Printronix SL5000r 参照ガイド

ページ / 394
Running Manual Calibrate
79
Running Manual Calibrate
Manual Calibrate should be performed only when the values derived from 
Auto Calibrate fail to improve the media sensors’ ability to sense label length 
indicators on the installed media. You must first enable “Admin User” in the 
PRINTER CONTROL menu before accessing or initializing Manual Calibrate 
in the CALIBRATE CTRL menu.
NOTE: Verify the Gap/Mark Sensor option (Gap, Mark, Advanced Gap, 
Advanced Notch, or Disable) matches the installed media. See 
“Sensing Different Media Types” on page 71.
Ensure the media sensors are horizontally positioned to permit 
sensing of the label length indicators. See “Positioning The Media 
Sensors” on page 66.
Ensure the Print Mode option selected in the QUICK SETUP menu 
matches the media installed. Select “Direct” for heat sensitive media 
(no ribbon required) or “Transfer” for thermal transfer media (ribbon 
required).
If you try to do a Manual Calibrate when Peel-Off Media Handling is 
enabled, the LCD will display, “CANNOT CALIBRATE/Disable Peel-
Off.” Before you can do a Manual Calibrate, you must select another 
media handling mode.
1.
Press 
 to place the printer in Menu mode.
2.
Press the 
↓ and 
 keys together until “ENTER SWITCH UNLOCKED” 
displays.
3.
Press 
 
until “PRINTER CONTROL” displays.
4.
Press 
↑ until “Admin User” displays, then press 
+
 until “Enable” displays.
5.
Press 
 to select Enable. An asterisk (*) appears next to “Enable.”
6.
Press 
 
until “CALIBRATE CTRL” displays.
7.
Press 
↓ until “Manual Calibrate/Run Calibrate” displays, then press the 
.
8.
Follow the instructions displayed on the LCD. Example: “REMOVE 
RBN&MEDIA/Press Enter” indicates that you must open the pivoting deck 
and remove the ribbon and media from under the printhead, close and 
lock the pivoting deck, and press the 
↵ 
key.
9.
During the last step of Manual Calibrate, the printer will advance the 
media and attempt to detect the label length indicators and stop at the 
Top-of-Form position. The Sensed Distance value will then display for 
one second. The calibrate is successful when the Sensed Distance value 
correctly matches that of the installed media. If “CALIBRATION FAIL/See 
Manual” displays, run Manual Calibrate again.
NOTE: The amount of media sampled during Manual Calibrate is based on 
the length of a label and the transitions detected without error, 
between a label and its label length indicators.
10. Press the PAUSE key until “OFFLINE” displays.
..
.
..
.
..
.