Printronix SL5000r 参照ガイド

ページ / 394
242
Chapter
3
PARALLEL PORT
PARALLEL PORT Submenus
Port Type
This menu item selects the type of printer parallel port interface to be used 
with the host.
The options are IEEE 1284 (the default), Disable, Centronics, and Ethernet.
NOTE: The Ethernet option is available only if E-Net Adapter is installed. 
When E-Net Adapter is installed, the IEEE 1284 and Centronics 
options do not display.
Data Bit 8
Enable (the default). The PI line is not passed directly from host to printer; 
all 8 bits are used for data bits, and characters in the hex 80-FF range can 
be accessed.
Disable. When the host PI line is enabled, data bit 8 internally indicates 
PI line status. To use the PI line, disable data bit 8, and enable the Host PI 
configuration option (under the PI Ignored option).
NOTE: Data bit 8 is interpreted as either data bit 8 or PI signal, but never 
both. When enabled as data bit 8, data bit 8 has priority over the PI 
signal, and all data above hex 7F is used to access character data 
and not to interpret PI line data.
Conversely, when data bit 8 is disabled and the PI signal is used, data 
bit 8 of the data is reserved for use as the PI function, and you cannot 
access characters in the hex 80-FF range. Therefore, to access 
characters in the hex 80-FF range, data bit 8 must be enabled.
PI Ignored
The PI (Paper Instruction) signal is used to control vertical paper motion.
Enable (the default). Ignores the PI signal and treats the data as 
characters or control codes.
Disable. Causes the printer to interpret the eight data lines as VFU 
commands when the PI signal is true.
Buffer Size in K
This option configures the amount of memory allocated for the Ethernet 
buffer. The range is 1-16 Kbytes, in 1-Kbyte increments.
The factory default is 16 Kbytes.