Printronix SL5000r 参照ガイド

ページ / 394
250
Chapter
3
SERIAL PORT
Request to Send
This configuration is part of hardware flow control and determines when the 
Request to Send (RTS) signal is generated. This signal indicates whether or 
not the printer is ready to receive data.
On-Line and BNF (factory default). Asserts the RTS signal when the 
printer is online and the internal serial buffer is not full.
Off-Line or BF. Asserts the RTS signal when the printer is offline or the 
internal serial buffer is full.
On-Line. Asserts the RTS signal when the printer is online.
False. Never asserts the RTS signal.
True. Continuously asserts the RTS signal.
Poll Character
This option is for the Series1 protocol. Whenever the printer receives this 
character, it sends a response to the host indicating the current state of the 
printer (see Series1 protocol).
The range is 00-FF Hex, and the factory default is 00 Hex.
Poll Response
This option is for the Series1 protocol. After receiving a poll character, the 
printer will wait the poll response time in milliseconds before sending the 
response.
The range is from 0 to 30 ms, and the factory default is 0 ms.
Idle Response
This option is for the Series1 protocol.
Disable (factory default).
Enable. The printer sends a response character every two seconds while 
the number of valid bytes in the buffer is less than 75 percent of the buffer 
size.