Printronix SL5000r 参照ガイド

ページ / 394
Fault Messages
319
BAR CODE QUIET
Zone too small
Yes
Data validation error:
Quiet Zone error.
1.
Fix application.
2.
Disable Quiet Zone Error 
reports.
BATT HIGH VOLT
Yes
This is the High Volt 
Alert that can be set by 
the user (factory 
default = 16.0 Volts). 
This fault detection is 
only supported when 
the ICP (Intelligent 
Control Panel) option is 
connected to the 
printer serial port and 
Battery Monitor = 
Enable in the 
BATTERY CONTROL 
menu.
1.
Raise the value in the High 
Volt Alert option in the 
BATTERY CONTROL 
menu.
2.
If High Volt Alert = 16.0 
Volts and the fault 
message remains, call 
your authorized service 
center.
BATT LOW VOLT
Yes
This is the Low Volt 
Alert that can be set by 
the user (factory 
default = 8.5 Volts). 
This fault detection is 
only supported when 
the ICP (Intelligent 
Control Panel) option is 
connected to the 
printer serial port and 
Battery Monitor = 
Enable in the 
BATTERY CONTROL 
menu. 
1.
Plug the power cart cable 
into an AC receptacle to 
recharge the battery.
2.
If recharging the battery 
fails to clear the fault, 
replace the battery or 
batteries.
BUFFER 
OVERFLOW
Yes
Host sent data after the 
printer buffer was full 
(serial interface).
1.
Make a configuration 
printout.
2.
Verify that the printer 
matches the host serial 
interface configuration 
settings for Data Protocol, 
Baud Rate, Data Bits, Stop 
Bits, Parity, Data Terminal 
Ready, and Request to 
Send.
7. Set printer serial interface 
parameters to match those 
of the host.
Table 17. LCD Message Troubleshooting (continued)
Displayed Message
Can User 
Correct?
Explanation
Solution