IPDS Exception Reporting
The following tables contain the exception reporting codes, which the printer
sends to the host in the NACK reply. These codes are in a three-byte format.
The first byte, byte 0, is the error group. The remaining two bytes, bytes 1 and
2, are the individual error identifiers. The following table shows the error group
meanings.
sends to the host in the NACK reply. These codes are in a three-byte format.
The first byte, byte 0, is the error group. The remaining two bytes, bytes 1 and
2, are the individual error identifiers. The following table shows the error group
meanings.
Command Reject: Indicates that the printer cannot recognize a received
command.
command.
Intervention Required: Indicates that the printer requires operator
intervention.
intervention.
Equipment Check: Indicates that a hardware error has occurred.
Data Check: Indicates that the printer detects a data error when receiving a
logical unit from the application program or that the printer detects a data error
while printing the page.
logical unit from the application program or that the printer detects a data error
while printing the page.
Specification Check: Indicates that the data parameters or values in a
received command are invalid.
received command are invalid.
Condition Requiring Host Notification: Indicates that the printer has
detected an error or condition that should be reported to the host computer.
detected an error or condition that should be reported to the host computer.
Byte 0
Error Type
Page
80
Command Reject
40
Intervention Required
10
Equipment Check
08
Data Check
04
Specification Check - Bar Codes
03
Specification Check - Graphics
02
Specification Check - General
01
Condition Requiring Host Notification