Printronix SL5000 参照マニュアル

ページ / 338
 24
Chapter
2
Configuring the P-Series Emulation with Control Codes
Configuring the P-Series Emulation with Control Codes
The remainder of this chapter describes the P-Series printer control language 
codes that may be sent from a host computer attached to the printer, in order 
to invoke and configure numerous P-Series emulation functions. 
Format for Control Code Descriptions
The following information is listed for each code function (where applicable).
Name
The title or function of the command.
ASCII Code The ASCII mnemonic for the command is shown. Command 
sequences are in 7-bit (ASCII) form.
Hex Code
The code or command sequence in hexadecimal numbers.
Dec Code
The code or command sequence in decimal numbers.
Purpose
The function(s) of the control code.
Comment
A discussion of the uses of the code or command sequence, 
including exceptions or limitations to its use.
Example
A sample is provided for some control codes when it is possible 
to illustrate the effect of a control code, or if a specific syntax is 
required to complete the program statement (i.e. Horizontal Tab 
set, Vertical Tab set/clear). 
IMPORTANT
If you specify any parameters for a control code other than the ones that 
are defined in the control code description, unpredictable results may 
occur.
Special Function Control Code-Control Code Header
A Special Function Control Code (SFCC) is used to extend the control code 
protocol. The SFCC is the control code introducer (or header); it is the first 
input in the sequence of parameters. The general control code sequence is:
(SFCC)(parameter 1)(parameter 2)...(parameter 
n)
P-Series codes can use any value from 1 through 255 (hex 01 through hex 
FF) as control code introducers. For example, bold print can be enabled in the 
P-Series protocol using any of the following control code introducers:
ASCII: SOH G
Hex: 01 47
Dec: 1 71
ETX G
03 47
3 71
ESC G
1B 47
27 71
^ G
5E 47
94 71
~ G
7E 47
126 71
NOTE: The SFCC has been set to ESC for all examples.