PDF 417
 253
PDF 417
The PDF417 structure is shown in Figure 18 and described below.
Figure 18. PDF417 Structure
Quiet Zone
Both ends of the bar code structure require blank quiet zones. The quiet 
zones must be at least 0.25 inches wide and completely blank to ensure 
accurate reading of the start/stop codes and to prevent adjacent bar codes 
from overlapping. Be sure to provide sufficient space on the form for the quiet 
zones.
Start/Stop Codes
The start/stop codes identify the leading and trailing end of the bar code. 
Data Field
PDF417 provides twelve modes to encode data. The first three are pre-
established (the remaining nine are user modes, which can be defined by 
users or industry associations according to specific applications):
1.
Extended Alphanumeric Compaction mode (EXC). Comprised of four 
sub-modes, this mode offers encodation of all printable ASCII characters. 
This is the default mode; ASCII Emulation uses shift or latch characters to 
enable other modes.
2.
Binary/ASCII Plus mode. This offers encodation for all ASCII characters, 
printable or not, and binary values.
3.
Numeric Compaction mode. This offers encodation for numeric values to 
a density of almost 3 digits per code word.
ASCII Emulation will automatically switch between modes to provide the 
smallest encodation for the data. 
DATA FIELD
QUIET
ZONE
QUIET
START
CODE
ZONE
STOP
CODE
LOWER GUARD BAND
UPPER GUARD BAND
SR, SC
POSITION