Printronix SL5000 参照マニュアル

ページ / 338
 256
Chapter
7
Bar Codes
Quiet Zone
The bar code structure requires a completely blank quiet zone which extends 
4.75 inches from the right edge of the mail piece. In addition, a minimum quiet 
zone of 0.040-inch above and below the bar code data must also be provided. 
You must provide sufficient space for this zone.
Start/Stop Code
The start and stop codes are referred to as “framing bars” in POSTNET. The 
start and stop codes are each one tall bar, one identifying the leading and 
trailing end of the bar code. The start/stop code is automatically produced 
with each bar code. The start/stop code structure permits bar code scanning 
in a left-to-right direction only.
Data Field
The bar code data produces a single field of 30 bars for a 5-digit field, 50 bars 
for a 9-digit data field, or 60 bars for an 11-digit data field. The bars are 
grouped in sets of five. Each set of five bars (comprised of two tall bars and 
three short bars) represents one of the five digits of the zip code, plus the 
four-digit zip code extension. If the Advanced Bar Code is used, an additional 
two-digit code is also added to make an 11-digit data field.
Check Digit
The sixth, tenth or twelfth digit represents the automatic check digit character 
for the 5, 9 or 11-digit data field, respectively. The check digit is added 
automatically to verify accurate scanning.
Telepen
The Telepen structure is shown in Figure 20 and described below.
Figure 20. Telepen Structure
DATA FIELD
QUIET
QUIET
START
STOP
LOWER GUARD BAND
CODE
CODE
ZONE
ZONE
OPTIONAL READABLE DATA FIELD
CHECK DIGIT
OPTIONAL
SR, SC
HEIGHT
POSITION
UPPER GUARD BAND