Printronix SL5000 参照マニュアル

ページ / 338
 288
Chapter
9
P-Series EVFU
End Load Code-Hex 1F or 6F
The end load code terminates the memory load program. The end load code 
is hex 1F when the PI signal line is disabled (low) or hex 6F when the PI line is 
enabled (high). Channel codes in excess of 192 channels received prior to the 
end load code are discarded.
Using the EVFU
Once the EVFU program has been enabled and loaded, sending the 
appropriate channel code to the printer causes any data in the buffer to print 
and positions the paper to the next line on the form having the specified 
channel number assigned in EVFU memory.
For a data byte to be recognized as an EVFU instruction, the following criteria 
must be met:
The PI signal line must be enabled and set high; and
Data bit 5 must be 0 (not set).
OR:
The PI signal line must be disabled or low; and
Data bit 5 must be 1 (set).
Given these conditions, the lower four bits of a byte specifies the EVFU 
channel number. Table 78 lists the EVFU channels and their equivalent data 
bytes with the PI signal line enabled; Table 79 lists the EVFU channels and 
their equivalent data bytes with the PI line disabled.