Wash Cycle (EZ 3710 / EZ 1710) 
Problem 
Possible Cause 
Repair Procedure 
1a. No power input. 
1a. Check that the cord is plugged 
in, and circuit breaker or fuse is OK. 
Test unit power switch. 
1b. No water pressure. 
1b. Check that fill hoses are 
connected that the water supply is 
turned on, and hoses are not 
kinked. 
1c. Drain outlet below 20" (water 
siphoning out) 
1c. Route drain hose through a 
clamp on the rear of the machine, at 
least 24" above the floor. 
1d. Door not closed tightly  
1d. Close door firmly, so that it 
latches. 
1e. Door Switch/Lock. 
1e. Set the washer knob to 
position#3. Switch On the power. 
Test for 115V AC across Pin#11 of 
small pressure switch and 
terminal#2 on the control module. If 
present the door switch is fine, if not 
present the door switch is defective. 
1f. Pressure Switch. (test with no 
water in the tub) 
1f. Switch Off the power. Check for 
continuity between pins 11 & 12 of 
small pressure switch, It should read 
zero resistance, if there is any 
reading then the small pressure 
switch is bad. Similarly there should 
be continuity (zero resistance) 
between pins 11 & 12 and pins 21 & 
22 of large pressure. 
1g. Timer 
1g. Switch On the power. Check for 
115V AC across the terminals of 
EVC(Hot water valve) & EVF(Cold 
water valve), if 115V is present the 
timer contacts are good or else 
defective. 
1. Won't fill 
1i. Water inlet valves. 
1i. If 115 vac is present across a 
water inlet valve coil and water 
pressure is present, the machine 
should fill. If not, the valve may be 
defective. 
2. Fills, won't  
agitate 
2a. Belt. 
2a. Check belt, adjust tension.