Wash Cycle (EZ 3710 / EZ 1710)
Problem
Possible Cause
Repair Procedure
1a. No power input.
1a. Check that the cord is plugged
in, and circuit breaker or fuse is OK.
Test unit power switch.
in, and circuit breaker or fuse is OK.
Test unit power switch.
1b. No water pressure.
1b. Check that fill hoses are
connected that the water supply is
turned on, and hoses are not
kinked.
connected that the water supply is
turned on, and hoses are not
kinked.
1c. Drain outlet below 20" (water
siphoning out)
siphoning out)
1c. Route drain hose through a
clamp on the rear of the machine, at
least 24" above the floor.
clamp on the rear of the machine, at
least 24" above the floor.
1d. Door not closed tightly
1d. Close door firmly, so that it
latches.
latches.
1e. Door Switch/Lock.
1e. Set the washer knob to
position#3. Switch On the power.
Test for 115V AC across Pin#11 of
small pressure switch and
terminal#2 on the control module. If
present the door switch is fine, if not
present the door switch is defective.
position#3. Switch On the power.
Test for 115V AC across Pin#11 of
small pressure switch and
terminal#2 on the control module. If
present the door switch is fine, if not
present the door switch is defective.
1f. Pressure Switch. (test with no
water in the tub)
water in the tub)
1f. Switch Off the power. Check for
continuity between pins 11 & 12 of
small pressure switch, It should read
zero resistance, if there is any
reading then the small pressure
switch is bad. Similarly there should
be continuity (zero resistance)
between pins 11 & 12 and pins 21 &
22 of large pressure.
continuity between pins 11 & 12 of
small pressure switch, It should read
zero resistance, if there is any
reading then the small pressure
switch is bad. Similarly there should
be continuity (zero resistance)
between pins 11 & 12 and pins 21 &
22 of large pressure.
1g. Timer
1g. Switch On the power. Check for
115V AC across the terminals of
EVC(Hot water valve) & EVF(Cold
water valve), if 115V is present the
timer contacts are good or else
defective.
115V AC across the terminals of
EVC(Hot water valve) & EVF(Cold
water valve), if 115V is present the
timer contacts are good or else
defective.
1. Won't fill
1i. Water inlet valves.
1i. If 115 vac is present across a
water inlet valve coil and water
pressure is present, the machine
should fill. If not, the valve may be
defective.
water inlet valve coil and water
pressure is present, the machine
should fill. If not, the valve may be
defective.
2. Fills, won't
agitate
agitate
2a. Belt.
2a. Check belt, adjust tension.