Equator ez1710 v 補足マニュアル

ページ / 10
 
8
 
Dry Cycle (EZ 3710 / EZ 1710) 
Problem 
Possible Cause 
Repair Procedure 
1a. No power input. 
1a. Check that cord is plugged in, and 
circuit breaker or, if fuse is OK. Test 
unit power switch. 
1b. Door not closed. 
1b. Close door firmly, so that it latches 
tightly. 
1.  No tumble 
action. 
1c. Belt. 
1c. Check belt, adjust tension. 
2a. No Heat coming into the 
drum 
2a. Check the Fuse Link according to 
the instructions in Appendix A and 
replace if necessary. 
2b. Timer not advanced beyond 
the cool-down period. 
2b. Set dryer timer for times longer 
than 15 minutes. 
2c. Thermostats open. 
2c. Check for continuity, at room 
temperature. 
2d. Thermal fuse open. 
2d. Check for continuity. 
2e. Heating elements. 
2e. Check resistance: 25 ohms 
maximum open. 
2.  Clothes 
cold and damp 
at the end of 
the dry cycle. 
2f. Dryer timer. 
2f. Test for 115 vac between terminals 
B1 & 22 of Heat Timer 
3a. Blocked filter. 
3a. Remove, clean, and replace filter. 
3b. *No cold water supply. 
3b. Cold water required for dryer to 
function properly. 
3.  Clothes hot 
and damp at 
the end of the 
dry cycle 
3c. * Machine not leveled. 
3c. Condenser water flow disturbed. 
Level unit and retest.