Champion d-h1t 仕様ガイド

ページ / 4
Door-type Extended Hood
Gas Heated
High Temperature Dishwasher
D-H1T GAS DOOR-TYPE
Dimensions shown in inches
1A
5A
7
2−5/8"
19−7/8"
2 HP
12−1/2"
67−1/2"
34"
27"
13−1/4"
25−1/4"
Clearance
92−1/2"
Door Removal
87"
Door Up
31−1/4"
10−1/4"
25−7/8"
8−1/2"
7−1/8"
1A
5A
1
7
2A
6
1B
3
*Hatco
Gas Booster
Mod. # PMG−100
8−7/8"
Details, Dimensions & Connections
Front View
Side View
Note:
The booster and machine come fully interplumbed
complete with a blended phosphate water treatment
system, pressure regulating valve, water hammer
arrestor, ASME temperature and pressure relief valve,
drain valve, circulator pump, and temperature gauges
installed and ready for connection to your water supply.
Utilities
Electrical
A.
Machine Connection (See Box)
B.
Booster connection requires 15 Amps @ 120/60/1
Hot Water
3/4" NPT hot water 140°F for 40°F rise booster.
3/4" NPT hot water 110°F for 70°F rise booster.
Flow pressure 20-22 psi.
Drain
A.
2" OD machine connection
B.
3/4" NPT relief valve to open drain
C.
1/2" NPT vent to open drain
D.
3/4" male threaded hose end
Gas
40°F rise - 58,000 BTU/hr.
70°F rise - 105,000 BTU/hr.
PMG-60 requires 1/2" NPT.
PMG-100 requires 3/4" NPT.
Gas Flue
4" OD exhaust
A.
Rear of booster
Length between table connections: 25-3/4"
Shipping weight crated:
775 lbs.
1−1/4" Roll
1−1/8"
24−1/4"
20−7/8"
7−1/4"
2−1/8"
Typical Table Construction
* Booster shown is the PMG100. Contact factory
for PMG60 drawings & electrical information.
Machine Load Amps
Minimum
Maximum
Supply Ckt. Overcurrent
Rated
Conductor
Protective
Voltage
Amps
Ampacity
Device
208/60/1
15
20
20
240/60/1
14
20
20
208/60/3
8
15
15
240/60/3
7
15
15
480/60/3
4
15
15
575/60/3
3
15
15
Gas