Automatic Fill/Low Water Heat Protection
A dual float switch controls the fill and heat circuit for its associated wash, eco-rinse,
or power wash tank as well as the electric or steam booster heat.
Identifying a dual float problem:
1.
Wash tank(s) fill constantly.
2.
Final rinse water runs constantly/No rinse tank heat.
3.
Tank heat will not come on.
4.
Final rinse booster heat will not come on.
System checks:
1.    Dual float assembly is clean and free of scale build-up.
2.    Stainless steel balls on the float assembly move up and down freely.
1.    All drain valves are fully closed.
2.    Incoming water supply Flow Pressure is 20-22 PSI.
3.    Fuses in control cabinet are good (Electric Heat Only).
4.    Steam supply and steam traps operate correctly.
5.    Tank Heat thermostats and/or high limit thermostats operate correctly.
6.    Booster heat thermostats and/or high limit thermostats operate correctly.
7.    Electric Eye Bypass switch is in the Automatic position.
Basic Service ________________
 
Electrical Service
Basic Service • Electrical
Note:
The Power Rinse Tank dual float controls the heat circuit of the OPTIONAL Champion
built-in booster (Steam or Electric). 120VAC Booster Control Voltage is supplied from
the rinse tank heat control thermostat to the booster heat control thermostat.