9
8
Check Final Rinse
Water Temperature
Check the final rinse water 
temperature during the 
final rinse cycle.
The final rinse water 
temperature gauge is located 
in the final rinse piping at
the top of the dishwasher.
The final rinse water tempera-
ture should be a minimum of 
180˚F/82˚C for (D-HBT, D-H1T).
The optimum final rinse temperature 
for (D-HBT, D-H1T) is 
180-195˚F/82-91˚C.
Check Final Rinse
Water Pressure
The final rinse water pressure gauge 
should indicate a flowing pressure of 
20-22 PSI/138-151.8 kPa during the 
final rinse cycle for all models.
A pressure reducing valve (PRV) is 
required if flow pressure exceeds 
20-22 PSI/138-151.8 kPa.
14
INITIAL START-UP
250
200
150
100
50
0
POWER
CYCLE
3 MIN
6 MIN
1 MIN
2 MIN
WASH CYCLE
RINSE PRESSURE
WASH TEMPERATURE
ON
OFF