Champion d-hb 仕様ガイド
For Electrical Heat D-HB w/70°F/39°C Rise Booster
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/3
57
60
60
240/60/3
64
70
70
480/60/3
29
35
35
575/60/3
25
30
30
Utilities
1 Electrical
(See Box)
2 Hot Water (DHB)
3/4” NPT hot water 140°F/60°C min for
40°F/22°C rise booster. 3/4” NPT hot water
110°F/43°C min for 70°F/39°C rise booster. Flow
pressure 20-22 psi. (138-151kPa)
Hot Water (DH1)
3/4” NPT 180ºF/82ºC hot water connection. Flow
presure 20-22 ps, (138-151 kPA)
3 Drain
2” O.D. connection. Max. flow rate
15 US gpm. (12imp.gpm/54/pm
For Electrical Heat D-HB w/40°F/22°C Rise Booster
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/1
71
80
80
240/60/1
79
90
90
208/60/3
40
50
50
240/60/3
45
50
50
480/60/3
20
25
25
575/60/3
16
20
20
SpeciFicationS
Capacity
Racks per hr. (NSF rated)
55
Wash tank US gal. (imp. gal/liters)
9 (7.5/3.4)
Motor horsepower
1
Water consumption
Gal. per hr. (max. use) US gal. (imp. gal/liters)
49 (41/186)
Gal. per rack (US gal. (imp. gal/liters)
.86 (0.74/3.4)
Temperatures °F/°C
Wash
150/66
Rinse
180/82
Heating
Tank heat, electric, (kW)
4.7
Tank heat, steam (lbs.per hr.
required at 15 psi flow pressure)
25
DHB
only
Electric booster (kW required for 40°F/22°C rise)
9
Electric booster (kW required for 70°F/39°C rise)
13
Steam booster (internally mounted)
(lbs. per hr. required for 40°F/22°C rise)
50
Steam booster (internally mounted)
(lbs.per hr. required for 70°F/39°C rise)
65
Time cycle in seconds
Wash
40
Rinse
8
Dwell
12
Total cycle
60
1-1/8"
24-1/4"
7-1/4"
1-1/4" Roll
2-1/8"
20-7/8"
typical table construction
Door-type High Temperature
Dishwashing Machine
D-HB/DH1
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 800/532-8591 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 800/263-5798 • Fax: 905/562-4618
Warning: Plumbing and electrical connection
should be made by qualified personnel who
will observe all the applicable plumbing,
sanitary and safety codes and the National
Electrical Code.
Plumbing Note: Because of the variation
Plumbing Note: Because of the variation
in house-supplied water and steam
pressure, pressure regulating valves (PRV’s)
for incoming water and steam supply are
needed. The PRV’s can be purchased from
Champion or obtained locally.
Note: Water Hammer Arrestor (meeting ASSE-
Note: Water Hammer Arrestor (meeting ASSE-
1010 standard or equivalent) to be supplied
(by others) in common water supply line at
service connection.
For Electric Heat
D-H1 Electrical Power Requirements
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
115/60/1*
48
60
60
208/60/1
35
40
40
240/60/1
37
40
45
208/60/3
20
25
25
240/60/3
21
25
25
480/60/3
9
15
15
575/60/3
7
15
15
*3kW wash tank heat