Champion d-hb 仕様ガイド

ページ / 4
  For Electrical Heat D-HB w/70°F/39°C Rise Booster
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
  Elec. 
Rated  Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/3 
57 
60 
60
  240/60/3 
64 
70 
70
  480/60/3 
29 
35 
35
  575/60/3 
25 
30 
30
Utilities
  1  Electrical 
(See Box)
 
2  Hot Water (DHB)
3/4” NPT hot water 140°F/60°C min for 
40°F/22°C rise booster. 3/4” NPT hot water 
110°F/43°C min for 70°F/39°C rise booster. Flow 
pressure 20-22 psi. (138-151kPa)
    Hot Water (DH1)
3/4” NPT 180ºF/82ºC hot water connection. Flow 
presure 20-22 ps, (138-151 kPA)
  3   Drain
2” O.D. connection. Max. flow rate  
15 US gpm. (12imp.gpm/54/pm
  For Electrical Heat  D-HB w/40°F/22°C Rise Booster
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
  Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/1 
71 
80 
80
  240/60/1 
79 
90 
90
  208/60/3 
40 
50 
50
  240/60/3 
45 
50 
50
  480/60/3 
20 
25 
25
  575/60/3 
16 
20 
20
SpeciFicationS
Capacity
Racks per hr. (NSF rated) 
 
55
Wash tank US gal. (imp. gal/liters) 
 
9 (7.5/3.4)
Motor horsepower 
 
1
Water consumption
Gal. per hr. (max. use) US gal. (imp. gal/liters) 
 
49 (41/186) 
Gal. per rack (US gal. (imp. gal/liters) 
   .86 (0.74/3.4)
Temperatures °F/°C
Wash  
 
150/66   
Rinse  
 
180/82
Heating  
Tank heat, electric, (kW) 
 
4.7
Tank heat, steam (lbs.per hr. 
required at 15 psi flow pressure) 
 
25
DHB
 only
Electric booster (kW required for 40°F/22°C rise) 
 
9
Electric booster (kW required for 70°F/39°C rise) 
 
13
Steam booster (internally mounted)  
(lbs. per hr. required for 40°F/22°C rise) 
 
50
Steam booster (internally mounted)  
(lbs.per hr. required for 70°F/39°C rise) 
 
65
Time cycle in seconds
Wash  
 
40
Rinse  
 
8
Dwell 
 
12 
Total cycle 
                                          60
1-1/8"
24-1/4"
7-1/4"
1-1/4" Roll
2-1/8"
20-7/8"
typical table construction
Door-type High Temperature  
Dishwashing Machine  
D-HB/DH1
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 800/532-8591 • Fax: 336/661-1979 • www.championindustries.com 
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 800/263-5798 • Fax: 905/562-4618
Warning: Plumbing and electrical connection 
should be made by qualified personnel who 
will observe all the applicable plumbing, 
sanitary and safety codes and the National 
Electrical Code.
Plumbing Note: Because of the variation 
in house-supplied water and steam 
pressure, pressure regulating valves (PRV’s) 
for incoming water and steam supply are 
needed. The PRV’s can be purchased from 
Champion or obtained locally.
Note: Water Hammer Arrestor (meeting ASSE-
1010 standard or equivalent) to be supplied 
(by others) in common water supply line at 
service connection.
  For Electric Heat 
   D-H1 Electrical Power Requirements
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
  Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
 115/60/1* 
48 
60 
60
  208/60/1 
35 
40 
40
  240/60/1 
37 
40 
45
  208/60/3 
20 
25 
25
  240/60/3 
21 
25 
25
  480/60/3 
15 
15
  575/60/3 
15 
15
*3kW wash tank heat