Champion eucc4 仕様ガイド
4'
[102]
1'-10"
[559]
2'-1"
[635]
9'-4" CL-CL
[2845]
5'-8"
[1727]
33-5/8"
[854]
6-1/4" [159]
6" [152]
36" [914]
4'
[1219]
[102]
4"
5-1/2" [140]
1-5/8"
[41]
38" [965]
12" [305]
Plumbing
Clearance
100" [2540]
Door
Removal
95" [2413]
Doors Up
24" [610]
Clearance
Overall Length “C”
7" [179]
CL
CL
7" [179]
4"
"A"
Load
4'
Wash
“B”
Unload
19" [483]
Clearance
62" [2337]
Machine
Height
10-1/2"
[267]
16" [406]
9-3/8" [238]
32"
2'
[610]
2'-6"
[762]
2
2
4A
3
1
4B
4B
4A
1
3
Start/Stop
HP
3
1
HP
HP
0.2
1/2 HP
Plumbing
Clearance
Wash
Prewash
Final
Rinse
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
Upright 24” Conveyor
Dual Rinse
Dishwashing Machine
EUCC SERIES
EUCC4
MOdULAR SECTIONS: Right to Left Operation
Notes:
Load Section (A) Standard
5 ft , contains 30” Prewash
Prewash also available in a
48” HD section Non-standard
load section available in
12” increments
Minimum load length 5ft
(includes 30” prewash)
Unload Section (B)
Standard 5 ft contains 24” Aux.
Rinse available in 12” increments
Built in electric booster requires
a 5 ft minimum unload
Built in steam booster requires
a mininum 6 ft unload
Blow dryer section adds 4ft to
overall length of machine
TABLE B - Booster Connection
40°F/22°C Rise – 15 kW
Electric built-in booster
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/3
42
60
60
240/60/3
36
45
45
480/60/3
18
25
25
Machine Only - Electric Heat
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/3
119
150
150
240/60/3
102
150
150
480/60/3
52
70
70
TABLE A - Machine Connection
Machine-steam
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/3
21
25
25
240/60/3
18
25
25
480/60/3
10
15
15
70°F/39°C Rise – 25 kW
Electric built-in booster
Minimum
Maximum
Supply Ckt. Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/3
70
90
90
240/60/3
60
80
80
480/60/3
30
40
40
Contact Factory for additional voltages.
Dimensions shown in inches and [millimeters]