Champion eucc4 仕様ガイド

ページ / 6
4'
[102]
1'-10"
[559]
2'-1"
[635]
9'-4" CL-CL
[2845]
5'-8"
[1727]
33-5/8"
[854]
6-1/4" [159]
6" [152]
36" [914]
4'
[1219]
[102]
4"
5-1/2" [140]
1-5/8"
[41]
38" [965]
12" [305]
Plumbing 
Clearance
100" [2540]
Door 
Removal
95" [2413]
Doors Up
24" [610]
Clearance
Overall Length  “C”
7" [179]
CL
CL
7" [179]
4"
"A"
Load
4'
Wash
“B”
Unload
19" [483]
Clearance
62" [2337]
Machine
Height
10-1/2"
[267]
16" [406]
9-3/8" [238]
32"
2'
[610]
2'-6"
[762]
2
2
4A
3
1
4B
4B
4A
1
3
Start/Stop
HP
3
1
HP
HP
0.2
1/2 HP
Plumbing
Clearance
Wash
Prewash
Final 
Rinse
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com 
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
Upright 24” Conveyor  
Dual Rinse 
Dishwashing Machine
EUCC SERIES
EUCC4
MOdULAR SECTIONS:  Right to Left Operation
Notes:
 Load Section (A) Standard  
5 ft , contains 30” Prewash
 
Prewash also available in a  
48” HD section Non-standard 
load section available in 
12” increments  
Minimum load length 5ft 
(includes 30” prewash) 
 
Unload Section (B)
 
Standard 5 ft contains 24” Aux. 
Rinse available in 12” increments 
 
Built in electric booster requires 
a 5 ft minimum unload
 
Built in steam booster requires  
a mininum 6 ft unload
 
Blow dryer section adds 4ft to 
overall length of machine
 
TABLE B - Booster Connection
 40°F/22°C Rise – 15 kW 
 Electric built-in booster
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/3  
42 
60 
60 
  240/60/3  
36 
45 
45
  480/60/3  
18 
25 
25
 Machine Only - Electric Heat
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/3  
119 
150 
150 
  240/60/3 
102 
150 
150
  480/60/3  
52 
70 
70
TABLE A - Machine Connection
 Machine-steam 
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/3  
21 
25 
25
  240/60/3  
18 
25 
25
  480/60/3  
10 
15 
15
 70°F/39°C Rise – 25 kW  
 Electric built-in booster  
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/3  
70 
90 
90 
  240/60/3 
60 
80 
80
  480/60/3  
30 
40 
40
Contact Factory for additional voltages.
Dimensions shown in inches and [millimeters]