Champion model 100 hdpw 仕様ガイド

ページ / 6
Volume crated:  
195 cu. ft.
Shipping weight crated:  
1100 lbs.
Dimensions shown in inches
TABlE B - BOOSTER CONNECTION
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com 
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
utilities
  1  Electrical
A  Machine connection (see Table A) 
B  Booster connection (see Table B)
  2  Hot Water
3/4” NPT 180°F/82°C min. hot water 
connection. (Machine without booster.) 
3/4” NPT 140°F/60°C min. hot water 
connection. (40°F/22°C rise booster) 
3/4” NPT 110°F/49°C min. hot water 
connection. (70°F/39°C rise booster)
Flow pressure 20-22 psi.
  3  Drain 
1-1/2” NPT machine connection.  
Maximum flow 15 gpm.
  4  Steam 
A  3/4” NPT machine connection.  
  Flow pressure 15-30 PSI. (Steam coil)
B  3/4” NPT machine connection.  
  Flow pressure 15-30 PSI.  
  (Steam injector)
  5  Condensate 
(no back pressure)
1/2” NPT machine return to boiler
  6  vents
A  Load end: 200 CFM @ 1/4” S.P.
B  Unload end: 400 CFM @ 1/4” S.P.  
  (With blower-dryer increase room    
ventilation by 600 CFM.)
64” Two Tank with Heavy Duty 36” Prewash  
Rack Conveyor  
Dishwashing Machine
Model 100 HdPW 
SPECIFICATIONS
Capacity 
Racks per hr. (NSF rated) 
277
Wash tank (US gal.) 
21
Conveyor speed (ft/min.) 
7.7
Motor Horsepower 
Drive  
1/6
Prewash 
1
Wash 2
Rinse 2
Water Consumption
US Gal. per hr. (max. use) 
124
US Gal. per rack 
.45
Heating
Tank Heat, electric (kW) 
25
Tank heat, steam  
(lbs/hr. required at  
15 PSI flow pressure) 
75
Electric booster (built-in) 
(kW supplied for 40°F rise) 
15
Electric booster  
(kW supplied for 70°F rise) 
24
Steam booster (lbs./hr.  
required for 40°F rise) 
120
Steam booster (lbs./hr.  
required for 70°F rise) 
205
venting
Load end (minimum CFM) 
200
Unload end (minimum CFM)  400
Standard 20” x 20”  
rack complement
Peg   
2
Flat   
1
venting Notes: 
Fabricated duct size:  
3-7/8” x 15-7/8” (Outside dimensions) 
Plumbing Notes:
 Because of the variation 
in house-supplied steam and water pressures, 
steam and water pressure regulating valves 
(PRVs) may be needed. (Water PRV is standard on 
machines with booster.) The PRVs can either be 
purchased from Champion or obtained locally.
Warning: 
Plumbing and electrical 
connections should be made by qualified 
personnel who will observe all the applicable 
plumbing, sanitary, safety codes and the 
National Electrical Code.
Note: 
Water Hammer Arrestor (meeting ASSE-
1010 standard or equivalent) to be supplied (by 
others) in common water supply line at service 
connection.
 40°F/22°C Rise – 15kW 
  Electric built-in booster (booster only)
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/3  
42 
50 
50
  240/60/3 
36 
45 
45
  480/60/3  
18 
25 
25
  575/60/3  
15 
20 
20
 70°F/39°C Rise – 24kW 
  Electric built-in booster (booster only)
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/3  
67 
80 
80
  240/60/3 
58 
70 
70
  480/60/3  
29 
35 
35
  575/60/3  
24 
30 
30
 Machine only
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/1 
171 
225 
225
  240/60/1  
150 
200 
200
  208/60/3  
95 
125 
125
  240/60/3  
83 
100 
100
  480/60/3  
41 
50 
50
  575/60/3  
32 
40 
40
TABlE A - MACHINE CONNECTION
 Machine and steam built-in booster
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/1 
41 
50 
50 
  240/60/1  
36 
50 
50
  208/60/3  
20 
25 
25
  240/60/3  
17 
25 
25
  480/60/3  
15 
15