25
Motors-Drive
Voltage:
Standard motors are multi-voltage
Low Voltage:
208-240VAC
1 Phase Only
High Voltage:
380/480/575VAC 3 Phase Only
208-240V 1Phase Wiring Diagram
To reverse motor rotation interchange yellow and orange leads.
Connect 208/240V
Power Here
Capacitor
10MFD
370VAC
Start
Winding
Run X
Winding
Run
Winding
Motor 1/6 HP
208/240V
White Wire
Orange Wire
Yellow WIre
Brown Wire
Black Wire
Red Wire
380/480/575/V 3Phase Wiring Diagram
To reverse motor rotation interchange any two external connections.
Connect 380/480/575V
3 Phase
Power Here
Motor 1/6HP
380/480/575 Volt
P6 Orange Wire
P5 Tan Wire
P4 Blue Wire
P5 Tan Wire
P4 Blue Wire
T6 Purple Wire
T9 Brown Wire
T9 Brown Wire
T4 Yellow Wire
T7 Pink Wire
T7 Pink Wire
T5 Black Wire
T8 Red Wire
T8 Red Wire
T3 Orange Wire
T1 Blue Wire
T2 Tan Wire
Conveyor Drive Jam Switch
• The conveyor jam switch stops the conveyor if something obstructs the movement of
• The conveyor jam switch stops the conveyor if something obstructs the movement of
of the rack conveyor.
• The light on the green start switch goes out and the pumps and the conveyor drive
• The light on the green start switch goes out and the pumps and the conveyor drive
motor stop running.
• After clearing the jam, push the green start button and insert another dishrack to
• After clearing the jam, push the green start button and insert another dishrack to
restart the pumps and conveyor. Be sure to wash any dishracks that may have been
stalled in the dishwasher prior to the jam condition.
Basic Service • Electrical