Champion model 44 仕様ガイド

ページ / 4
Gas Heated Water Saver
High Temperature Rack Conveyor
Single-tank Dishwashing Machine
44WS GAS RACK CONVEYOR
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 800/532-8591 • Fax: 336/661-1979 • www.championindustries.com
SPECIFICATIONS
Capacities
Racks per hr. (NSF rated)
126
Wash tank (gal.)
20
Conveyor speed (ft./min.)
3.5
Motor horsepower
Drive
1/6
Wash
2
Water consumption
Gal. per hr. (max. use)
124
Temperatures °F
Wash
160
Rinse
180
Heating
Gas Booster
Natural
130,000 BTU/hr.
LP
130,000 BTU/hr.
40° rise & 70° rise Booster
Natural
200,000 BTU/hr.
LP
200,000 BTU/hr.
Venting
Load end (minimum cfm)
200
Unload end (minimum cfm)
400
Standard 20" x 20" Rack Complement
Flat
1
Peg
2
Gas
Suggested Table
Construction
2-1/4"
1-3/4"
1-1/2"
Can be up
to 10"
5/8"
21"
8"
Machine Load Amp 
Minimum
Maximum
Supply Ckt.
Overcurrent
Rated
Conductor
Protective
Voltage
Amps
Ampacity
Device
208/60/1
16
20
20
240/60/1
15
20
20
208/60/3
8
15
15
240/60/3
8
15
15
480/60/3
4
15
15
575/60/3
3
15
15
2-3/4"
HATCO
GAS BOOSTER
MOD. # PMG-200
Front View
3C
1B
2
3B
6
4B
4A
3A
1A
7-1/2"
13-3/4"
19-5/8"
25-3/8"
31-7/8"
5"
26
Door
Cowl
Cowl
4"
4"
8"
8"
20-3/4"
Clear
34"
Load
Height
44"
60"
5"
89"
Door
Removal
82"
Door
Open
Height
58-1/2"
Machine
Height
7"
12"
Plumbing
Clearance
Right-to-Left Operation
1'
98-1/2"
42-1/2"
29-3/4"
6"
44"
8-3/4"
13"
1
1-1/8"
5-3/4"
20-3/4"
12"
12"
35-7/8"
47-7/8"
59-7/8"
6-1/4"
1-1/2"
24-1/8"
5-1/4"
27-3/8"
23-3/8"
Plan View
2
6B
3B
1A
4B
4A
3A
2
1B
6C
5
5
5
3B
1B
25"
28-1/2"
36"
6"
8"
12-1/2"
16"
2"
2"