Champion model 66 drwspw 仕様ガイド

ページ / 6
Volume crated:  
152 cu. ft.
Shipping weight crated:  
800 lbs.
Dimensions shown in inches
Warning: Plumbing and electrical connections should be made by qualified personnel who will 
observe all the applicable plumbing, sanitary, safety codes and the National Electrical Code.
Note: Water Hammer Arrestor (meeting ASSE-1010 standard or equivalent) to be supplied  
(by others) in common water supply line at service connection.
Plumbing Notes: Because of the variation in house-supplied steam and water pressures, steam and 
water pressure regulating valves (PRVs) may be needed. (Water PRV is standard on machines with booster.) 
The PRVs can either be purchased from Champion or obtained locally.
Venting Notes: Fabricated duct size: 3-7/8” x 15-7/8” (Outside dimensions) 
 Machine only
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/1 
120 
150 
150
  240/60/1  
105 
150 
150
  208/60/3  
74 
100 
100
  240/60/3  
65 
90 
90
  480/60/3  
33 
45 
45
  575/60/3  
25 
35 
35
Table a - Machine connecTion
 Machine and steam built-in booster
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/1 
42 
60 
60
  240/60/1  
37 
50 
50
  208/60/3  
29 
40 
40 
  240/60/3  
26 
35 
35
  480/60/3  
12 
15 
15
  575/60/3  
10 
15 
15
Table b - Machine & boosTer connecTion
 70°F/39°C Rise –  16 kW 
  Machine and Electric built-in booster 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/1  
197 
250 
250
  240/60/1  
172 
225 
225
  208/60/3  
119 
150 
150
  240/60/3 
103 
125 
125
  480/60/3  
52 
70 
70
  575/60/3  
41 
50 
50
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com 
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
Utilities
 
1  Electrical Connection
a  Machine only (see Table A) 
b  Machine & booster (see Table B)
 
2  Hot Water
3/4” NPT 180°F/82°C min. hot water 
connection. (Machine without booster.) 
3/4” NPT 140°F/60°C min. hot water 
connection. (40°F/22°C rise booster) 
3/4” NPT 110°F/49°C min. hot water 
connection. (70°F/39°C rise booster)
Flow pressure 20-22 psi.
 
3  Drain 
1-1/2” NPT machine connection.  
Maximum flow 15 gpm.
 
4  Steam 
a  3/4” NPT machine connection.  
  Flow pressure 15-30 PSI. (Steam coil)
b  3/4” NPT machine connection.  
  Flow pressure 15-30 PSI.  
  (Steam injector)
 
5  Condensate (no back pressure)
1/2” NPT machine return to boiler
 6  Vents
a  Load end: 200 CFM @ 1/4” S.P.
b  Unload end: 400 CFM @ 1/4” S.P.  
  (With blower-dryer increase room    
ventilation by 600 CFM.)
Model 66 drWsPW
44” Single Tank Water Saver with 22” Prewash
High Temperature Rack Conveyor  
Dishwashing Machine with
Dual Stage Rinse
44” Single Tank Water Saver with 22” Prewash
High Temperature Rack Conveyor  
Dishwashing Machine with
Dual Stage Rinse
44” Single Tank Water Saver with 22” Prewash
High Temperature Rack Conveyor  
Dishwashing Machine with
Dual Stage Rinse
Model 66 drWsPW
Model 66 drWsPW
sPeciFicaTions
Capacity
 
Racks per hr. (NSF rated) 
  148
Wash tank (US gal.) 
 
21
Conveyor speed (ft/min.) 
 
4.1
Motor Horsepower 
  Drive 
 
1/6 
Wash 
 
Prewash 
 
Dual Rinse 
  1/10
Water Consumption
US Gal. per hr.  
(max. use) 
 
80
US Gal. per rack 
 
.54
Heating
Wash Tank, electric (kW) 
 
15
DualRinse Tank electric (kW)   
3.3 
Tank heat, steam (lbs/hr. 
  required at 15 PSI flow pressure) 
75
Electric booster (built-in) 
(kW supplied for 40°F rise)     
10
Electric booster  
(kW supplied for 70°F rise)   
16
Steam booster (lbs./hr.  
required for 40°F rise) 
 
50
Steam booster (lbs./hr.  
required for 70°F rise) 
 
 80
Venting 
Load end (minimum CFM) 
  200
Unload end (minimum CFM)    400
Standard 20” x 20”  
rack complement
Peg   
 
2
Flat   
 
1
 40°F/22°C Rise –  10 kW 
 Machine and Electric built-in booster 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/1  
168 
225 
225
  240/60/1  
147 
200 
200
  208/60/3  
102 
125 
125
  240/60/3  
89 
110 
110
  480/60/3  
45 
60 
60
  575/60/3  
37 
45 
45
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com