Champion uh-100b インストール手順

ページ / 84
3
  Electrical Connection
 
Installation Guide
Electrical Connection
Electrical Connection
NOTE:
The electrical connection must be performed by a qualified electrician in 
accordance with local codes and the National Electrical Code.
WARNING:
For models UH100B, UH170B, and UH200B disconnect the main power at 
the main disconnect switch. Tag and lockout the switch to indicate that work 
is being done on the circuit.
1.  Refer to the connection diagrams below for proper dishwasher power 
connection at the dishwasher main terminal block (MTB).
2.  (a) Electrical supply must be a  
single phase 3-wire plus ground which includes a current carrying neutral. 
 
(b) For a three phase the electrical supply must be a 4-wire plus ground which 
includes a current carrying neutral.  
3.  The dishwasher MTB is located at the front right-side of dishwasher.
4.  Remove the dishwasher's lower front access panel by removing the two truss head 
screws.
5.  Carefully bump the lower front access panel up as you pull forward. Be careful not 
to damage the pressure gauge mounted on the left side of the panel (not supplied 
on models UL100,  UH-100, or UH100B).
6.  Remove the main terminal block cover. The machine's electrical schematic is 
located on the inside of the front panel. Check the min/max data on the schematic.
7.  Loosen the two screws securing the MTB. Then, pull the MTB up and forward.
L1
L3
L2
N
208-230
VAC
208-230
VAC
208-230
VAC
115 VAC
L1
L2
N
208-230
VAC
115VAC
For machines prior 
to S/N 14326