I N S T A L L A T I O N  
Plumbing Requirements 
¾  WATER SUPPLY – Hot and Cold Water should be supplied by ½” or ¾” water 
lines, with the ¾” being the preferred method. 
¾  DRAINS – A 1-1/2” minimum waste 
connection is required. If equipped, the 
scrapping sink typically has a 1-1/2” NPS 
connection, while the wash, rinse, and 
sanitize sinks typically have a 2” NPS 
connection. 
Pump 
¾  PUMPS – The wash tank pumps will need 
to be piped to a floor drain. This uses a ½” 
NPT connection. 
Bottom View of Pump Assembly
 
Electrical Requirements 
WARNING
 – Electrical Hazard – May result in electrical shock, burns, or death 
¾  POWER – The power requirements for your unit are listed on the serial plate 
located at the rear of the control panel. In the case of a control panel mounted on 
top of the backsplash, the serial 
plate will be located on the 
inside of the control panel lid. 
DELUXE
Taskmaster PP3 
¾  CONNECTION – The single 
point electrical connection is 
located on the 20 amp fuse 
block which is located inside the 
control panel. See wire diagram 
for details. 
¾  POWER SOURCE – A dedicated service panel is required and should be located 
on the wall or behind the control panel within 10 feet of the unit. 
To ensure service reliability and safety, use water tight connections and the proper wire 
gauge. A wire diagram is located inside the control panel lid and also at the back of this 
manual. 
Obey local, state, and national regulatory agency requirements when installing 
electrical connections to this unit.
49