BASIC SERVICE (CONT.)
Hi-Limit Switch
On machines with electric tank and boosters, a separate thermostat is installed that interrupts the
power if the temperature exceeds a preset limit. When the over temperature condition is resolved,
the red button located on top of the switch, must be pushed to reset the power to the elements.
Pressure Reducing Valve (PRV)
A 3/4”  PRV for the water supply or 1-1/4” for steam booster, is required if the incoming water
supply exceeds 20-22 PSI(138-151kPa) for water or 30 PSI for steam flowing pressure. The
PRV’s should be installed in the incoming supply lines before the machine connection.
Water Hammer Arrestor
Whenever a booster heater is installed in the final rinse line a water hammer arrestor shall be
installed between the booster outlet and the final rinse inlet valve. This helps to prevent the
knocking or hammering sound of the water as it flows through the pipes.
Wash Pump/Motor 
The wash pump/motor is a closed centrifugal pump that is rated 7-1/2 HP running at 3600 RPM.
The motor is rated 3 phase, 60 hertz, and is multi-voltage.