Undercounter High Temperature  
Dishwashing Machine  
with Built-in Booster Heater
UH-200b
UH
-200b 
U
nderco
U
nter
Due to an ongoing value analysis program at Champion, specification contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com 
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 800/263-5798 • Fax: 905/562-4618
Dimensions shown in inches and [millimeters]
Warning 
Plumbing and 
electrical connections should 
be made by qualified personnel 
who will observe all the 
applicable plumbing, sanitary 
and safety codes and the 
National Electrical Code.
Field convertible to accept 3 phase power
Plan View
Volume crated:
 
 15 cu. ft./0.42 cu.m.
Shipping weight crated:
 
 215 lbs./97.5 kg. 
Utilities
1
Electrical
208-240/60/1; 3 wire plus ground, (See Box). 
208-240/60/3; 4 wire plus ground, (See Box).
2
 Hot Water
1/2” supply; 140°F/60°C Min. hot water connection for 40°F/22°C rise booster; 
110°F/43°C Min. hot water connection for 70°F/39°C rise booster. Incoming supply 
pressure must maintain a Flow pressure of 20-22 PSI (Pressure reducing valve, PRV, 
supplied by customer or may be purchased unmounted from Champion).  
Machine equipped with 3/4” [19] hose connector.
3
 Pumped Drain
5/8” [15.9] I.D. flexible reinforced hose, 6 ft. [1829] long.  
Max. drain flow 15 US gpm. [12.5 imp gal] Max. drain height 3 ft. [914]
3
2
1
40-1/2"
[1029]
14-3/4"
[375]
Clearance
33-3/4" [857]
1
2
3
24" [610]
25" [635]
CHAMPION
UH200B
4" [102]
15-3/4" [400]
2" [51]
3
2
1
40-1/2"
[1029]
14-3/4"
[375]
Clearance
33-3/4" [857]
1
2
3
24" [610]
25" [635]
CHAMPION
UH200B
4" [102]
15-3/4" [400]
2" [51]
3
2
1
40-1/2"
[1029]
14-3/4"
[375]
Clearance
33-3/4" [857]
1
2
3
24" [610]
25" [635]
CHAMPION
UH200B
4" [102]
15-3/4" [400]
2" [51]
Front View
SPecIFIcAtIonS
Capacities
 
Cycle time (seconds) 
90
 
Racks per hr. (NSF) 
30
Motor horsepower
 
Wash 
1
Water consumption
 
U.S. Gal./Imperial Gal.  
 
(Max. use) per hr. 
28.2/23.2 
 
 
U.S. Gal./Imperial Gal.  
 
 
per rack  
.9/.75
Temperatures °F/°C 
 
Wash 
150/66 
 
Rinse 
180/82 
Heating
 
Tank heat, electric, kW 
2.0
 
Electric booster  
 
(kW) required for 40°F/22°C rise) 
6
 
Electric booster 
 
 
(kW) required for 70°F/39°C rise) 
9
Time Cycle in Seconds
 
Wash 
70
 
Rinse 
15
 
Total cycle 
90
Standard 20” x 20” [508 x 508] 
Rack Complement
 
Dish 
1
 
Open 
1
  UH-200 without booster 
  750 Watt tank heat
  Elec. Specs. 
Rated Amps 
  115/60/1 
12 
115V
115V
208V
L1
L2
N
G
Note: 
Electrical supply service 
must be a 3-wire plus ground for 
connection shown.
Side View
UH-200B with 40°F/22°C Rise Booster
Elec. Specs.
Rated 
Amps
Minimum 
Supply Ckt. 
Conductor 
Ampacity
Maximum 
Overcurrent 
Protective 
Device
208/60/1
32
40
40
240/60/1
36
40
40
208/60/3
22
30
30
240/60/3
24
30
30
UH-200B with 70°F/39°C Rise Booster
Elec. Specs.
Rated 
Amps
Minimum 
Supply Ckt. 
Conductor 
Ampacity
Maximum 
Overcurrent 
Protective 
Device
208/60/1
45
60
60
240/60/1
50
60
60
208/60/3
29
35
35
240/60/3
33
40
40