Champion model 84 仕様ガイド

ページ / 6
Dimensions shown in inches
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com 
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
84” Two Tank
High-Temperature
Rack Conveyor Dishwashing Machine
Model 84 
84” Two Tank
High-Temperature
Rack Conveyor Dishwashing Machine
Model 84 
84” Two Tank
High-Temperature
Rack Conveyor Dishwashing Machine
Model 84 
Volume crated:  
130 cu. ft.
Shipping weight crated:  
850 lbs.
Dimensions shown in inches
Warning: Plumbing and electrical connections should be made by qualified personnel who will 
observe all the applicable plumbing, sanitary, safety codes and the National Electrical Code.
Note: Water Hammer Arrestor (meeting ASSE-1010 standard or equivalent) to be supplied (by 
others) in common water supply line at service connection.
Plumbing Notes: Because of the variation in house-supplied steam and water pressures, steam 
and water pressure regulating valves (PRVs) may be needed. (Water PRV is standard on machines with 
booster.) The PRVs can either be purchased from Champion or obtained locally.
Venting Notes: Fabricated duct size: 3-7/8” x 15-7/8” (Outside dimensions) 
 Machine only
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/1 
162 
200 
200
  240/60/1  
142 
175 
175
  208/60/3  
90 
110 
110
  240/60/3  
80 
100 
100
  480/60/3  
40 
50 
50
  575/60/3  
31 
40 
40
Table a - Machine connecTion
 Machine and steam built-in booster
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/1 
32 
40 
40
  240/60/1  
29 
40 
40 
  208/60/3  
15 
20 
20
  240/60/3  
14 
20 
20
  480/60/3  
15 
15
Table b - boosTer connecTion
Utilities
 
1  Electrical
a  Machine connection (see Table A) 
b  Booster connection (see Table B)
 
2  Hot Water
3/4” NPT 180°F/82°C min. hot water 
connection. (Machine without booster.) 
3/4” NPT 140°F/60°C min. hot water 
connection. (40°F/22°C rise booster) 
3/4” NPT 110°F/49°C min. hot water 
connection. (70°F/39°C rise booster)
Flow pressure 20-22 psi.
 
3  Drain 
1-1/2” NPT machine connection.  
Maximum flow 15 gpm.
 
4  Steam 
a  3/4” NPT machine connection.  
  Flow pressure 15-30 PSI. (Steam coil)
b  3/4” NPT machine connection.  
  Flow pressure 15-30 PSI. (Steam    
injector)
 
5  Condensate (no back pressure)
1/2” NPT machine return to boiler
  6  Vents
a  Load end: 200 CFM @ 1/4” S.P.
b  Unload end: 400 CFM @ 1/4” S.P.  
  (With blower-dryer increase room    
ventilation by 600 CFM.)
sPeciFicaTions
Capacity 
Racks per hr. (NSF rated) 
356
Wash tank (US gal.) 
21
Conveyor speed (ft/min.) 
9.9
Motor Horsepower 
Drive  
1/6
Wash 3
Rinse 3
Water Consumption
US Gal. per hr. (max. use) 
131
US Gal. per rack 
.37
Heating
Tank Heat, electric (kW) 
25
Tank heat, steam  
(lbs/hr. required at  
15 PSI flow pressure) 
75
Electric booster (built-in) 
(kW supplied for 40°F rise) 
15
Electric booster  
(kW supplied for 70°F rise) 
24
Steam booster (lbs./hr.  
required for 40°F rise) 
75
Steam booster (lbs./hr.  
required for 70°F rise) 
120
Venting
Load end (minimum CFM) 
200
Unload end (minimum CFM)  400
Standard 20” x 20”  
rack complement
Peg   
2
Flat   
1
 40°F/22°C Rise – 15kW 
  Electric built-in booster (booster only)
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/3  
42 
50 
50
  240/60/3 
36 
45 
45
  480/60/3  
18 
25 
25
  575/60/3  
15 
20 
20
 70°F/39°C Rise – 24kW 
  Electric built-in booster (booster only)
 
 
 
Minimum 
Maximum 
 
 
 
Supply Ckt.  Overcurrent 
 
Elec. 
Rated 
Conductor 
Protective 
  Specs. 
Amps 
Ampacity 
Device
  208/60/3  
67 
80 
80
  240/60/3 
58 
70 
70
  480/60/3  
29 
35 
35
  575/60/3  
24 
30 
30