Part 1: GENERAL SPECIFICATIONS
4
1.5 Electrical Power Requirements
1.5.1 Power Requirements for Steam Heat
Machine Full Load Amps 6.9A
Operating Currents (440V/60/3 Supply)
Steam Heated
Wash motor
2.7 Amps
Rinse motor
2.7 Amps
Drive motor
0.4 Amps
Control Circuit
1.1 Amps
1.5.2 Power Requirements for Electric Heat
Machine Full Load Amps 6.9A
Operating Currents (440V/60/3 Supply)
Wash motor
2.7 Amps
Rinse motor
2.7 Amps
Drive motor
0.4 Amps
Control Circuit
1.1 Amps
Each heat circuit has a separate power source.
Circuit
Voltage
Booster Rise
Machine
Power Requirement
Hz/Ph
(Steam)
Full Load Amps (125% Service Factor)
Motor/Control
440/60/3
70
°
6.9 Amps
9.0 Amps
Heat
Voltage
KW
   Amps
  Power Requirement
Circuit
Hz/Ph          (Electric)
Full Load
(125% Service Factor)
Wash
tank heat
440/60/3
20KW
27 Amps
33 Amps
Power Rinse
tank heat
440/60/3
30KW
40 Amps
50 Amps
Final Rinse
Booster (40
°
rise)
(One cannister)
440/60/3
37.8KW
49.6 Amps
62 Amps
Final Rinse
Booster (70
°
rise)
(Two cannisters)
Cannister 1
440/60/3
32.8KW
43 Amps
53.8 Amps
Cannister 2
440/60/3
32.8KW
43 Amps
53.8 Amps
Total KW for 70
°
rise is 65.6 KW