Intel RS2BL080 ユーザーズマニュアル

ページ / 42
Appendix A: Event Messages and Error Codes 
Intel® RAID Controller RS2BL080 Technical Product Specification 
Appendix A: Event Messages and Error Codes 
This appendix lists the Intel
®
 RAID Web Console 2 events that may appear in the event log.  
The Intel
®
 RAID Web Console 2 utility monitors the activity and performance of all controllers in 
the server and any devices attached to them. When an “event” such as the completion of a 
consistency check or the removal of a physical drive occurs, an event message is displayed in 
the log, which is displayed at the bottom of the Intel
®
 
RAID Web Console 2 screen. The 
messages are also logged in the Windows Application Log (Event Viewer). Error event levels 
are: 
ƒ 
Progress: This is a progress posting event. Progress events are not saved in NVRAM. 
ƒ 
Information: Informational message. No user action is necessary. 
ƒ 
Warning: A component may be close to a failure point. 
ƒ 
Critical: A component has failed, but the system has not lost data. 
ƒ 
Fatal: A component has failed and data loss has occurred or will occur. 
ƒ 
Dead: A catastrophic error has occurred and the controller has failed. This is seen only 
after the controller has been restarted.  
 
The following table lists the Intel
®
 RAID Web Console 2 event messages: 
Table 16 Event Messages 
Number  
Type  
Description  
Information 
Firmware initialization started (PCI ID %04x/%04x/%04x/%04x)  
Information 
Firmware version %s  
Fatal 
Unable to recover cache data from TBBU  
Information 
Cache data recovered from TBBU successfully  
Information 
Configuration cleared  
Warning 
Cluster down; communication with peer lost  
Information 
%s ownership changed from %02x to %02x  
Information 
Alarm disabled by user  
Information 
Alarm enabled by user  
Information 
Background initialization rate changed to %d%%  
10 
Fatal 
Controller cache discarded due to memory/battery problems  
11 
Fatal 
Unable to recover cache data due to configuration mismatch  
12 
Information 
Cache data recovered successfully  
13 
Fatal 
Controller cache discarded due to firmware version incompatibility  
14 
Information 
Consistency Check rate changed to %d%%  
15 
Dead 
Fatal firmware error: %s  
16 
Information 
Factory defaults restored A249 
17 
Warning 
Flash downloaded image corrupt  
18 
Critical 
Flash erase error  
 
 
Revision 1.0
 
 
Intel order number E64388-001 