Motorola DCT2000 インストール手順

ページ / 70
D i a g n o s t i c s
BBBB ---- 5555
D C T   2 0 0 0   I n s t a l l a t i o n   M a n u a l
Table B-3 lists the error codes:
T a b l e   B - 3
E r r o r   c o d e s
I n i t i a l i z a t i o n   s t a t u s   e r r o r s
E r r o r   C o d e
O S D
C a u s e
R e m e d y
E 00*
NO ERROR
Indicates normal condition after initialization
Not applicable
E 01*
NOT CONNECTED
DCT 2000 did not receive a connect message
Send a connect message
Restore out-of-band signal
E 02
PWR CYCLE
Init Error
Box needs a Power Cycle to
recover
E 03
DRAM
DRAM error
Not used at this time
E 04
DPSRAM
DP-SRAM error
Not used at this time
E 07
ROM
ROM verification failure
Power cycle box; if repetitive,
return for repair
E 08
RAM
Faulty RAM, ROM, EEPROM, or POST failure
(this is a hardware failure)
Return DCT 2000 for repair
E 09
BATTERY
Dead battery or memory has not been
initialized; occurs if battery fails to keep the
RAM alive during power-down; causes
DCT 2000 to be disconnected
Return DCT 2000 for repair;
requires factory initialization
message
E 10
SERIALNO
Invalid serial number
Not used at this time
E 11
UNIT ADDRESS
Invalid unit address
Return DCT 2000 for repair;
requires a unit creation message
E 12
POST
POST failed
Not used at this time
E 13
BOOT
Sys_boot initialization failure
Power cycle box; if repetitive,
return for repair
E 14
STARTUP
DCT 2000 system startup failure
Power cycle box; if repetitive,
return for repair
E 15
TSI INVALID
TSI structure is corrupted
Power cycle box; if repetitive,
return for repair
E 16
FLASH BAD NUMBER
Bad flash number specified for
InitiateFlashPlatform
Error logged, ignore
E 17
BAD PLATVAL
Bad platform validation step number
Error logged, ignore
*E 00 and E 01 cannot be displayed while the DCT 2000 is off. The other errors will display on