4.  Recommendations of Command, Status and Layer definition 
 
All Commands, Statuses and Layers will be defined other specific document. 
[MANDATORY]
 The product MUST have Commands and the Statuses same as a remote controller buttons (IR 
controller) of the product. 
All Commands are required working by discrete as ON/OFF commands. (It means that do not support TOGGLE 
command only. ) 
All Commands and Statuses are defined same character size except ACK/NAK on the product. ( Recommended 
character length : 3~6 characters ) 
It permits attaching 0x0A character to a reply characters from the product. In this case, must suppose that the object is 
followed altogether. 
 
Recommend to supports numbers or values direct setting command, if it has variable numbers or values.