Be extremely careful when removing the lamp housing. In the unlikely 
event that the lamp ruptures, small glass fragments may be generated. 
The lamp module is designed to contain most of these fragments, but 
use caution when removing it. Before replacing a ruptured lamp, clean 
the lamp compartment and dispose of cleaning materials. Wash hands 
after lamp replacement.  
Hg – Lamp contains mercury. Manage in accordance with local 
disposal laws. See www.lamprecycle.org.
5
Carefully remove the lamp housing. Dispose of the lamp in an environ-
mentally proper manner. 
6
Install the new lamp housing. Be careful to attach the connector on the 
lamp housing to the connector inside the projector. These connectors are 
located near the leveling foot.
7
Tighten all three screws.
8
Plug in the power cable then press the Power button to turn the projec-
tor back on, then reset the lamp hour timer. 
Resetting the lamp timer
To reset the lamp timer, navigate to the Settings>Service menu and select 
Reset
 Lamp Hours
remove lamp housing
reset lamp time in Service menu