Grandstream ht-503 ユーザーズマニュアル

ページ / 37
 
Grandstream Networks, Inc. 
HT503 User Manual 
Page 30 of 37  
sent periodically. 
Send Anonymous 
When set to “Yes”, the “From” header will have value “anonymous”, blocking Caller ID. 
Pre-configured account user Id is put in the P-Asserted-Identity field. 
Anonymous Call 
Rejection 
Default is No.  If set to “Yes”, incoming calls with anonymous Caller ID will be rejected 
with a 486 busy message. 
Special Features 
Default is Standard.  Choose the selection to meet some special requirements from 
Softswitch vendors. 
Session Expiration 
Grandstream implemented SIP Session Timer. The session timer extension enables 
SIP sessions to be periodically “refreshed” via a SIP request (UPDATE, or re-INVITE. 
Once the session interval expires, if there is no refresh via a UPDATE or re-INVITE 
message, the session will be terminated.  
 
Session Expiration is the time (in seconds) at which the session is considered timed 
out, if no successful session refresh transaction occurs beforehand. The default value 
is 180 seconds.
 
Min-SE 
The minimum session expiration (in seconds).  The default value is 90 seconds.  
Caller Request Timer 
If selecting “Yes” the phone will use session timer when it makes outbound calls if 
remote party supports session timer. 
Callee Request Timer 
If selecting “Yes” the phone will use session timer when it receives inbound calls with 
session timer request.  
Force Timer 
If selecting “Yes” the phone will use session timer even if the remote party does not 
support this feature. Selecting “No” will allow the phone to enable session timer only 
when the remote party support this feature.  
 
To turn off Session Timer, select “No” for Caller Request Timer, Callee Request Timer, 
and Force Timer.
 
UAC Specify Refresher 
As a Caller, select UAC to use the phone as the refresher, or UAS to use the Callee or 
proxy server as the refresher.  
UAS Specify Refresher 
As a Callee, select UAC to use caller or proxy server as the refresher, or UAS to use 
the phone as the refresher. 
Force INVITE 
Session Timer can be refreshed using INVITE method or UPDATE method. Select 
“Yes” to use INVITE method to refresh the session timer.  
Preferred Vocoder 
The HT503 supports different Vocoder types including 
1.  G.711 A/µ law,  (Displayed as PCMA/PCMU) 
2. G.723.1, 
 
3.  G.726 (Supports bit rates 16, 24, 32, and 40)  
4. G.729A/B/E, 
 
5. iLBC 
Users can configure Vocoders in a preference list that will be included with the same 
preference order in SDP message. 
G723 Rate 
This defines the encoding rate for G723 vocoder. Default setting is 6.3kbps. 
iLBC Frame Size 
This sets the iLBC size in 20ms or 30ms 
iLBC Payload Type 
This defines the payload type for iLBC. Default value is 97. The valid range is between 
96 and 127. 
G726-16 Payload 
Defines payload type for G726-16.  Default value is 100.  Range is from 96 to 127. 
G726-24 Payload Type 
Defines payload type for G726-24.  Default value is 99.  Range is from 96 to 127. 
G726-40 Payload Type 
Defines payload type for G726-40.  Default value is 103.  Range is from 96 to 127. 
G729E Payload Type 
Defines payload type for G729E.  Default value is 102.  Range is from 96 to 127 
VAD 
Default is No. VAD allows detecting the absence of audio and conserves bandwidth by 
preventing the transmission of “silent packets” over the network. 
Symmetric RTP 
Default is No.  When set to “Yes” the device will change the destination to send RTP 
packets to the source IP address and port of the inbound RTP packet last received by 
the device. 
Fax Mode 
T.38 (Auto Detect) FoIP by default, or fax Pass-Through (must use PCMU/PCMA) 
 
Firmware 1.0.0.9 
Last Updated: 9/2007