Uniden d3288-2 ユーザーガイド

ページ / 30
English - 
Liquid Damage
CAUTION: If the base is covered in liquid, disconnect the adapter & phone 
cord from the wall before touching it.
If the liquid is only on the exterior housing of the base or handset, wipe it off and 
use as normal. If you can hear liquid inside the housing:
Remove all compartment covers, and disconnect all cables and cords.
If liquid is leaking from any vent or hole, turn the phone so that vent faces down. 
If not, place the largest vent face down.
Let dry for at least 3 days. Check for liquid inside the phone before replacing 
compartment covers & reconnecting cords.
Resetting Stations
If you have problems with the base, unplug the base to reset it. Plug it back in after at 
lease a minute. If you have problems with a cordless handset or want to replace one, 
reset it:
Press & hold 
enD
 and 
#
 at the same time until you see the 
System Reset
 menu.
If you still have the base the handset is registered to, select 
Deregister HS
, then 
select the handset you want to reset. If you don’t have that base anymore, select 
Base Unavailable
.
To confirm, select 
Yes
. The handset displays 
Handset not registered
Registering Handsets
If you see a “not registered” message on a handset, you must register it to a base 
before using it.
On the base, open the menu and select 
Register Accy
.
On the handset, press and hold #; the handset displays 
Registering
.
Wait until the display says 
Registration Complete
 (about 30 seconds), then pick up 
the handset; press 
HOMe/flasH
.
If you don’t hear a dial tone or the display says 
Registration Failed
, charge 
the battery completely, then try again.
1.
2.
3.
1.
2.
3.
1.
2.
3.
Adapter and Battery Information
AC adapter Base
Charger
Part number
PS-0034
PS-0035
Input voltage
120V AC, 60 Hz
Output voltage 7.8V AC @ 
450mA
8V AC @ 
300mA
Use only the supplied AC adapters.
Use the proper adapter for the base & any 
chargers.
Do not place the unit in direct sunlight or subject 
it to high temperatures.

Battery pack (with normal use)
Part number
BT-1022
Capacity
300mAh, 2.4V DC
Talk time
about 7 hours
Standby time
about 7 days
Battery life
about 1 year
Replace the battery when the talk or standby time 
becomes noticeably reduced. For replacements, 