OSC 2 “SEMITONE” values
The following table shows how the control change values transmitted/
received by the OSC2 page “SEMITONE” setting correspond to the value 
of the parameter.
“TYPE BAL” values
The following table shows how the control change values transmitted/
received by the FILT1 page “TYPE BAL” setting correspond to the value of 
the parameter.
VC FILT
FRMNT.SFT
off
0...25: –2, 26...51: –1, 52...76: 0, 77...102: +1, 103...127: +2
0...25: –2, 26...51: –1, 52...76: 0, 77...102: +1, 103...127: +2
FC.OFFSET
off
0/1: –63, 2: –62...63: –1, 64: 0, 65: +1...127: +63
0/1: –63, 2: –62...63: –1, 64: 0, 65: +1...127: +63
RESO
off
0...127
0...127
FC.MOD.INT
off
0/1: –63, 2: –62...63: –1, 64: 0, 65: +1...127: +63
0/1: –63, 2: –62...63: –1, 64: 0, 65: +1...127: +63
EF SENS
off
0...126, 127: HOLD
0...126, 127: HOLD
VC AMP
VC LEVEL
off
0...127
0...127
DIRCT.LVL
off
0...127
0...127
Value (transmitted, received)
SEMITONE Value (transmitted, received)
SEMITONE
0...2
–24
66, 67
+1
3...5
–23
68...70
+2
6, 7
–22
71...73
+3
8...10
–21
74, 75
+4
11...13
–20
76...78
+5
14, 15
–19
79, 80
+6
16...18
–18
81...83
+7
19, 20
–17
84...86
+8
21...23
–16
87, 88
+9
24...26
–15
89...91
+10
27, 28
–14
92...94
+11
29...31
–13
95, 96
+12
32, 33
–12
97...99
+13
34...36
–11
100, 101
+14
37...39
–10
102...104
+15
40, 41
–9
105...107
+16
42...44
–8
108, 109
+17
45...47
–7
110...112
+18
48, 49
–6
113, 114
+19
50...52
–5
115...117
+20
53, 54
–4
118...120
+21
55...57
–3
121, 122
+22
58...60
–2
123...125
+23
61, 62
–1
126, 127
+24
63...65
0
Value (transmitted, received) TYPE BAL
0
–24LPF
1…30
Intermediate the characters between –24LPF and –12LPF.
31…33
–12LPF
34…62
Intermediate the characters between –12LPF and HPF.
63…65
HPF
66…94
Intermediate the characters between HPF and BPF.
95…97
BPF
98…126
Intermediate the characters between BPF and THRU.
127
THRU