Zhone 2000 ユーザーガイド

ページ / 296
C o n f i g u r a t i o n
119
Figure 4.84
Start Mode Selection Menu
NOTICE: 
The loop start and ground start features apply to ATM signaling only.
Each option on this menu is described in detail below.
Set All Ports to Loop
Start
1
Type “1” to select Set All Ports to Loop Start. The IAD sets all ports to 
Loop Start and saves the configuration.
2
Press any key to return to the Start Mode Selection menu or press escape to 
continue with other voice path configuration.
3
Reset the IAD when you finish voice path configuration.
Set All Ports to Ground
Start
To set All Ports to Ground Start, follow the steps below.
1
Type “2” on the Start Mode Selection menu (Figure 4.84) to select Set All 
Ports to Ground Start. The IAD sets all ports to Ground Start and saves the 
configuration.
2
Press any key to return to the Start Mode Selection menu or press Escape to 
continue with other voice path configuration.
3
Reset the IAD when you finish voice path configuration.
NOTICE: 
For “Ground Start” applications all elements in the voice path must be 
set to “Ground Start.”
Display Start Mode To display Start Mode, follow the steps below.
1
To display a list of telephone ports and their current start mode, type “3” on 
the Start Mode Selection menu (Figure 4.84). The IAD displays a list of 
ports and the mode of each.
2
Press any key to return to the Start Mode Selection menu or press Escape to 
continue with other voice path configuration.
Configure Individual
Port
To configure Start Mode on an individual port, follow the steps below.
1
Type “4” on the Start Mode Selection menu (Figure 4.84). For each port, 
the IAD prompts you to type one of the following options for each port.
1—Loop Start
2—Ground Start
3—DID Wnk