Zhone 2000 ユーザーガイド

ページ / 296
174
2 0 0 0 - A 2 - G B 2 3 - 0 0
Display G2237 xDSL Statistics (21xx)
This report shows xDSL status indicators.
Near-End CRC Last
Number of seconds of cyclic redundancy check error 
counts.
Near-End CRC Last
Number of minutes of cyclic redundancy check error 
counts.
Failure Counters Overall
Total overall failure frames.
Local SEF
Count of local (near-end) severely errored frames.
Local LOS
Count of local (near-end) loss of signal frames.
Remote SEF
Count of remote (far-end) severely errored frames.
Remote LOS
Count of remote (far-end) loss of signal frames.
ADSL Standard
Current status of the ADSL standard in use.
Parameter
Description
Operational State
Current operation state.
Start Progress
Current start progress.
Operational Seconds 
Total Operation Time in Seconds
Up/Down Counter
No. of times modem has come up.
Received SNR
No. of SNR (Signal-to-Noise Ration) received.
Mean SQ Error
No. of mean SQ error used to compute received signal 
to noise ratio.
Initial Received SNR
No. of the Initial Received SNR (Signal-to-Noise 
Ration)
Loop Attenuation
Current level of Loop Attenuation
Actual PSD Mask
Actual PSD mask is used for the line code comparison. 
It is acknowledged that an optimized PSD mask can be 
decided only after line code decision is made. The 
transmit power back-off of remote HTU
Framer Sync
Current framer synchronization status: In-Sync / Out of 
Sync
LOSW Status
Current status of LOSW (Loss of Sync Defect): ON / 
OFF
Total Seconds
Total seconds of statistics gathering.
Errored Seconds
Total errored seconds received of CRC and LOSW 
errors found.
Parameter