Zhone 7995 ユーザーガイド

ページ / 154
7. Testing
7-8
 
 September 2004
7990-A2-GB20-20
When a Send and Monitor 511 test is active, a count of bit errors is displayed next 
to the test duration, and the ResetMon virtual function key is available for use. 
Type r or R or select the ResetMon virtual function key to reset the error count.
SYNC Data Port Tests (Model 7995)
To access the SYNC Data Port Tests screen, follow this menu selection sequence:
Main Menu
TestSYNC Data Port Tests
Use the Command column to start or stop a test. When the Status column shows 
that a test is Inactive, Start is displayed; when a test is Active, Stop is displayed. 
Position the cursor at the desired Start or Stop command and press Enter. The 
Results column displays the test duration. 
main/test/data                                                 
                                                                     Model: 7995
                               SYNC DATA PORT TESTS
Test                         Command     Status        Results              
--------------------------------------------------------------------------------
Local Loopbacks
  Data Terminal Loopback:    Start       Inactive      00:00:00
  Data Channel Loopback:     Start       Inactive      00:00:00
  Repeater Loopback:         Start       Inactive      00:00:00
Remote Loopbacks
  Send Remote DCLB:   Down   Send        Inactive      00:00:00
--------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu      MainMenu   Exit