Configuring the Unit Using the Internal Switches
Use internal Switchpacks S3 and S4 to manually configure the unit. .
HANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES
This product is designed to protect sensitive components from 
damage due to electrostatic discharge (ESD) during normal 
operation. When performing installation procedures, 
however, take proper static control precautions to 
prevent damage to equipment. If you are not sure 
of the proper static control precautions, contact 
your nearest sales or service representative.
Procedure
 
To configure the unit using internal Switchpacks S3 and S4:
1. Power off the unit.
2. Remove the enclosure cover:
Use a Phillips screwdriver to remove the two screws from the top of the unit.
Push a flat-blade screwdriver through the slots on both sides of the housing to 
free the four inner latches.
3. Locate Switchpack S3 on the circuit board using 
.
4. Set Switch 1 on Switchpack S3 to ON to enable Switchpacks S3 and S4.
5. After you enable the switchpacks, you must set the switches to your desired 
configuration: 
For Model 7995, refer to 
For Model 7996, refer to 
6. Replace the cover and fasten it with the two screws.