Zhone 7995 ユーザーガイド

ページ / 154
7. Testing
7-6
 
 May 2002
7990-A2-GB20-00
Remote Send Line Loopback
The local unit initiates this test by sending a line loopback Up or Down command 
to the remote unit for 10 seconds. When the remote unit detects the loopback Up 
command, it puts itself into line loopback and lights the front panel test LED. The 
remote unit remains in loopback until it receives a loopback Down command or the 
remote unit’s test timeout value is exceeded. The Send Line Loopback tests both 
units. External equipment can be used to verify the link.
Procedure
 
To run a Remote Send Line Loopback:
1. Position the cursor at the Up or Down selection next to Send Line Loopback 
on the DSL Tests or DSL & G.703 Tests screen.
2. Press the spacebar to select either Up or Down.
3. Position the cursor at the Send command next to the Up or Down selection.
4. Press Enter.
The local unit stops sending the loopback command automatically after 
10 seconds. You cannot stop the Send Line Loopback test manually.
The Remote Network Send Line Loopback cannot be started when any other 
loopback test is active on the DSL interface.
G.703
Port
E1
LIU
Framer
Framer
Transceiver
02-17118
E1
LIU
Framer
Framer
Transceiver
AIS
Local
Remote