T r o u b l e s h o o t i n g   a n d   D i a g n o s t i c s
7-5
Symptom
Probable Cause
Corrective Action
Power indicator is not lit
Power is not available 
to the IAD
Ensure the power cord is 
securely connected.
Ensure the power cord is 
plugged into a live outlet.
Ensure the power switch is on.
If powered by an adapter, 
ensure the correct adapter is 
used.
LAN Link indicator is not lit
Incorrect Ethernet 
connection
Ensure an Ethernet cable is 
properly connected to the IAD 
and its upstream connection.
No dial tone is present
Incorrect PVC set for 
voice channel
Verify these settings:
VPI: 0 to 255
VCI: 0 to 65535
(default PVC 0/39)
IAD is improperly 
provisioned at the 
voice gateway
Incorrect network 
provisioning
Incorrect directory 
number at the Class 5 
switch
Verify and correct 
provisioning of IAD as 
required (refer to page 5-2).
Check and correct network 
provisioning at DSLAM, 
network switches, etc.
Check and correct as required
Cannot receive or send data
Incorrect PVC set for 
data channel
Verify these settings:
VPI: 0 to 255
VCI: 0 to 65535
(default PVC 0/38)
View Interface (page 5-12) 
and Media statistics 
(page 5-20) to check the pack 
receive and send status.
Incorrect network 
setup
Check and correct network 
setup as necessary.
If IAD is configured as a router:
Incorrect or missing 
LAN or WAN IP 
address
Ensure that both the LAN and 
WAN IP addresses are 
configured.
Incorrect or missing 
default static route
Review the routing table and 
correct as necessary 
(page 5-26).