Zhone 2004 ユーザーガイド

ページ / 216
A d m i n i s t r a t i o n
3-15
Trace Route
1
Type “T” on the Utilities menu and press Enter.
2
Type the IP address or complete host name. If you enter a host name, you 
must also enter the domain name (i.e., mycomputer.mydomain.com). The 
IAD displays each hop, as shown in the following sample report:
Configure Console Baud Rate
To set the console port baud rate (for connecting to Hyperterminal via a serial 
cable), follow these steps:
1
Type “Z” on the Utilities menu to display the following menu:
2
Type “0” to reset the baud rate to the default (19200 bps), or select a 
specific baud rate and press Enter.
3
Reset the IAD to use the new console port settings. Be sure the terminal 
settings are the same as the console port settings.
NOTICE: 
The new baud rate table will take effect only after you either recycle the 
power or reset the IAD.
Configure Console Timeout
To maintain security, you can set the amount of time a console or Telnet 
session remains alive before termination due to inactivity. To set the timeout 
period, follow these steps:
1
Type “V” on the Utilities menu to display the Console Timeout Status and a 
prompt for you to enter a new Timeout value or disable the Timeout.
2
Type a value between 0-60 minutes (default 3) and press Enter or type “0” 
(zero) to disable the Timeout feature.