Zhone 2004 ユーザーガイド
C o n f i g u r a t i o n
4-39
2
Enter a zero (0) in each port location to disable the port; enter a 1 in each
port location to enable the port. Press Enter to complete the step. The IAD
displays the AAL2/LES Manual Configuration menu.
port location to enable the port. Press Enter to complete the step. The IAD
displays the AAL2/LES Manual Configuration menu.
Set CAS Refreshing Rate
1
Type “R” on the AAL2/LES Manual Configuration menu to set the CAS
refresh rate.
refresh rate.
2
Enter a zero (“0”) to disable CAS refresh, or enable CAS refresh by
entering a non-zero refresh rate value. The IAD displays the AAL2/LES
Manual Configuration menu.
entering a non-zero refresh rate value. The IAD displays the AAL2/LES
Manual Configuration menu.
3
Reset the IAD before enabling Idle CAS refresh.
Enable/Disable Idle CAS Refreshing
1
Type “I” on the AAL2/LES Manual Configuration menu to enable or
disable idle CAS refreshing. You can only enable idle CAS refresh when
CAS refresh is enabled (immediately preceding).
disable idle CAS refreshing. You can only enable idle CAS refresh when
CAS refresh is enabled (immediately preceding).
2
Type “E” to enable Idle CAS refresh, or D to disable Idle CAS refresh. The
IAD displays the AAL2/LES Manual Configuration menu, and indicates in
the message section that the change in the Idle CAS refresh will take place
when the IAD is reset.
IAD displays the AAL2/LES Manual Configuration menu, and indicates in
the message section that the change in the Idle CAS refresh will take place
when the IAD is reset.
Change Maximum CPS-SDU Size; 45/64 Octets
Type “S” on the AAL2/LES Manual Configuration menu to switch the
maximum CPS payload size between 45 and 64 octets. The IAD displays the
AAL2/LES Manual Configuration menu. Included in the settings is a payload
size message indicating 45 or 64 octets.
maximum CPS payload size between 45 and 64 octets. The IAD displays the
AAL2/LES Manual Configuration menu. Included in the settings is a payload
size message indicating 45 or 64 octets.
Set “Combine Use” Timer
1
Type “T” on the AAL2/LES Manual Configuration menu to modify the
combined use timer (in 5 ms increments).
combined use timer (in 5 ms increments).
2
Type the new timer period and press Enter. The IAD updates the setting and
displays the menu.
displays the menu.
Enable/Disable User State Control
Type “U” on the AAL2/LES Manual Configuration menu to enable or disable
user state control by toggling the state. The IAD displays the AAL2/LES
Manual Configuration menu. Included in the settings is a USC message
indicating that it is enabled or disabled.
user state control by toggling the state. The IAD displays the AAL2/LES
Manual Configuration menu. Included in the settings is a USC message
indicating that it is enabled or disabled.
Enable/Disable Dialed Digit
1
Type “E” on the AAL2/LES Manual Configuration menu to enable or
disable dialed digit by toggling the state. The IAD displays the AAL2/LES
Manual Configuration menu. Included in the settings is a message
indicating that dialed digit will be enabled or disabled after reset.
disable dialed digit by toggling the state. The IAD displays the AAL2/LES
Manual Configuration menu. Included in the settings is a message
indicating that dialed digit will be enabled or disabled after reset.