ZyXEL 793H ユーザーガイド
Chapter 34 Firmware and Configuration File Maintenance
P-793H User’s Guide
327
4 Launch the TFTP client on your computer and connect to the ZyXEL Device. Set the
transfer mode to binary before starting data transfer.
5 Use the TFTP client (see the example below) to transfer files between the ZyXEL
Device and the computer. The file name for the configuration file is “rom-0” (rom-zero,
not capital o).
not capital o).
Note that the telnet connection must be active and the SMT in CI mode before and during the
TFTP transfer. For details on TFTP commands (see following example), please consult the
documentation of your TFTP client program. For UNIX, use “get” to transfer from the ZyXEL
Device to the computer and “binary” to set binary transfer mode.
TFTP transfer. For details on TFTP commands (see following example), please consult the
documentation of your TFTP client program. For UNIX, use “get” to transfer from the ZyXEL
Device to the computer and “binary” to set binary transfer mode.
34.3.7 TFTP Command Example
The following is an example TFTP command:
tftp [-i] host get rom-0 config.rom
Where “i” specifies binary image transfer mode (use this mode when transferring binary files),
“host” is the ZyXEL Device IP address, “get” transfers the file source on the ZyXEL Device
(rom-0, name of the configuration file on the ZyXEL Device) to the file destination on the
computer and renames it config.rom.
“host” is the ZyXEL Device IP address, “get” transfers the file source on the ZyXEL Device
(rom-0, name of the configuration file on the ZyXEL Device) to the file destination on the
computer and renames it config.rom.
34.3.8 GUI-based TFTP Clients
The following table describes some of the fields that you may see in GUI-based TFTP clients.
to read about configurations that disallow TFTP and FTP
over WAN.
34.3.9 Backup Via Console Port
Back up configuration via console port by following the HyperTerminal procedure shown
next. Procedures using other serial communications programs should be similar.
next. Procedures using other serial communications programs should be similar.
1 Display menu 24.5 and enter “y” at the following screen.
Table 126 General Commands for GUI-based TFTP Clients
COMMAND
DESCRIPTION
Host
Enter the IP address of the ZyXEL Device. 192.168.1.1 is the ZyXEL Device’s
default IP address when shipped.
Send/Fetch
Use “Send” to upload the file to the ZyXEL Device and “Fetch” to back up the file on
your computer.
Local File
Enter the path and name of the firmware file (*.bin extension) or configuration file
(*.rom extension) on your computer.
Remote File
This is the filename on the ZyXEL Device. The filename for the firmware is “ras” and
for the configuration file, is “rom-0”.
Binary
Transfer the file in binary mode.
Abort
Stop transfer of the file.