Amana AEP222VA インストール手順

ページ / 24
11
6. Use 
³⁄₈" nut driver to connect the neutral (white) wire to the 
center terminal block post with one of the 10–32 hex nuts.
7. Connect line 1 (black) and line 2 (red) wires to the outer 
terminal block posts with 10-32 hex nuts.
8. Securely tighten hex nuts.
9. Replace terminal block access cover.
3-wire connection: Direct Wire
Use this method only if local codes permit connecting ground 
conductor to neutral supply wire.
1. Pull the conduit through the strain relief on cord/conduit plate 
on bottom of range. Allow enough slack to easily attach the 
wiring to the terminal block.
2. Attach terminal lugs to line 1 (black), bare (green) ground, and 
line 2 (red) wires. Loosen (do not remove) the set screw on the 
front of the terminal lug and insert exposed wire end through 
bottom of terminal lugs. Securely tighten set screw to torque 
as shown in the following Bare Wire Torque Specifications 
chart.
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
3. Use 
³⁄₈" nut driver to connect the  bare (green) ground wire to 
the center terminal block post with one of the 10–32 hex nuts.
4. Connect line 1 (black) and line 2 (red) wires to the outer 
terminal block posts with 10-32 hex nuts.
5. Securely tighten hex nuts.
6. Replace terminal block access cover.
A. 10–32 hex nut
B. Line 1 (black)
C. Bare (green) ground wire
D. Ground-link screw
E. Neutral (white) wire
F. Line 2 (red)
G. Terminal lug
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Line 2 (red) wire
E. Bare (green) ground wire
F. Line 1 (black) wire
B
A
G
E
C
D
F
A
B
C
D
E
F
A. Terminal lug
B. Set screw
C. Line 1 (black) wire
D. Bare (green) ground wire
E. Line 2 (red) wire
Wire Awg
Torque
8 gauge copper
25 lbs-in. (2.8 N-m)
6 gauge aluminum
35 lbs-in. (4.0 N-m)
A. 10–32 hex nut
B. Line 1 (black)
C. Ground-link screw
D. Bare (green) ground wire
E. Line 2 (red)
F. Terminal lug
A
B
C
D
E
B
F
A
E
D
C