AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Data based on all channels driven.
watts in
watts out
dissapated
Btu/hr
kcal/hr
At Idle (sleep mode)
40
0
40
137
34
1/8th Power Pink Noise
8 Ohms/Ch.
1000x2
Typical of program material 
16 Ohms Bridge
2000
just at clip.
4 Ohms/Ch.
1000x2
8 Ohms Bridge
2000
2 Ohms/Ch.
1000x2
4 Ohms Bridge
2000
70/100V/Ch.
1000x2
140/200V Bridge 2000
1/3rd Power Pink Noise
8 Ohms/Ch.
1000x2
Typical of program material
16 Ohms Bridge
2000
with severe clipping.
4 Ohms/Ch.
1000x2
8 Ohms Bridge
2000
2 Ohms/Ch.
1000x2
4 Ohms Bridge
2000
70/100V/Ch.
1000x2
140/200V Bridge 2000
485
1655
417
11.6
5.8
990
674
316
1080
272
13.7
6.9
1190
705
304
1036
261
12.3
6.2
1064
672
392
1338
337
11.3
5.6
980
676
351
1198
302
6.7
3.4
639
257
382
1304
329
7.2
3.6
602
251
290
988
249
7.0
3.5
563
255
307
1049
264
6.6
3.3
546
256
CTs 2000
Load
Rated 
Power
Line Current 
120VAC
Line Current 
230VAC
Watts 
Thermal Dissipation