Electrical 
Grounding Instructions 
In the event of a malfunction or breakdown, 
grounding provides a path of least resistance for 
electric current to reduce the risk of electric 
shock. This tool is equipped with an electric cord 
having an equipment-grounding conductor and a 
grounding plug. 
The plug must be plugged into a matching outlet 
that is properly installed and grounded in 
accordance with all local codes and ordinances. 
Do not modify the plug provided – if it will not fit 
the outlet, have the proper outlet installed by a 
qualified electrician. 
Improper connection of the equipment-
grounding conductor can result in a risk of 
electric shock. The conductor with insulation 
having an outer surface that is green with or 
without yellow stripes is the equipment-
grounding conductor. If repair or replacement of 
the electric cord or plug is necessary, do not 
connect the equipment-grounding conductor to a 
live terminal. 
Check with a qualified electrician or service 
personnel if the grounding instructions are not 
completely understood, or if in doubt as to 
whether the tool is properly grounded. 
Use only 3-wire extension cords that have 3-
prong grounding plugs and 3-pole receptacles 
that accept the tool’s plug. 
Repair or replace damaged or worn cord 
immediately. 
115 Volt Operation Only 
Referring to Figure 5: 
As received from the factory, your drill press is 
ready to run at 115-volt operation. This drill 
press, when wired for 115 volt, is intended for 
use on a circuit that has an outlet and a plug that 
looks like the one illustrated in (A). A temporary  
adapter, which looks like the adapter shown in 
(B), may be used to connect this plug to a two-
pole receptacle if a properly grounded outlet is 
not available. The temporary adapter should 
only be used until a properly grounded outlet 
can be installed by a qualified electrician. This 
adapter is not applicable in Canada. The green 
colored rigid ear, lug, or tab, extending from the 
adapter, must be connected to a permanent 
ground such as a properly grounded outlet box. 
 
Figure 5 
Extension Cords 
Make sure your extension cord is in good 
condition.  When using an extension cord, be 
sure to use one heavy enough to carry the 
current your machine will draw.  An undersized 
cord will cause a drop in the line voltage 
resulting in power loss and overheating. The 
table below shows the correct size to use 
depending on the cord length and nameplate 
ampere rating.  If in doubt, use the next heavier 
gauge. Remember, the smaller the gauge 
number, the heavier the cord.  
 
Cord Length 
AWG 
 
  
0
0 – 25ft 
0
16 
 
  
2
5 – 50ft 
0
14 
Important:  Make certain the receptacle in 
question is properly grounded.  If you are not 
sure, have a registered electrician check the 
receptacle.