Grounding Instructions 
General Information 
 
This Band Saw must be 
grounded while in use to protect the operator 
from electric shock. 
In the event of a malfunction or breakdown, 
grounding provides a path of least resistance for 
electric current to reduce the risk of electric 
shock. This tool is equipped with an electric cord 
having an equipment-grounding conductor and a 
grounding plug that looks similar to the plug in 
Figure 15. The plug must be inserted into a 
matching outlet that is properly installed and 
grounded in accordance with all local codes and 
ordinances. 
Do not modify the plug provided. If it will not fit 
the outlet, have the proper outlet installed by a 
qualified electrician. 
Improper connection of the equipment-
grounding conductor can result in a risk of 
electric shock. The conductor, with insulation 
having an outer surface that is green with or 
without yellow stripes, is the equipment-
grounding conductor. If repair or replacement of 
the electric cord or plug is necessary, do not 
connect the equipment-grounding conductor to a 
live terminal. 
 
Figure 15 
Check with a qualified electrician or service 
personnel if the grounding instructions are not 
completely understood, or if in doubt as to 
whether the tool is properly grounded.  
Repair or replace a damaged or worn cord 
immediately. 
115 Volt Operation 
As received from the factory, your bandsaw is 
ready to run at 115-volt operation. This bandsaw
 
 
is intended for use on a circuit that has an outlet 
and a plug that looks like the one illustrated in 
Figure 4. An adapter with a grounding ear 
(Figure 16) may be used temporarily to connect 
this plug to a two-pole receptacle as shown 
(Figure 11), if a properly grounded outlet is not 
available. The temporary adapter should only be 
used until a properly grounded outlet can be 
installed by a qualified electrician. This adapter 
is not applicable in Canada. The green colored 
rigid ear, lug, or tab, extending from the adapter, 
must be connected to a permanent ground such 
as a properly grounded outlet box, as shown in 
Figure 5. 
 
Figure 16 
Extension Cords 
Use only three wire extension cords that have 
three-prong grounding plugs and three-pole 
receptacles that accept the tool’s plug. 
Make sure the cord is in good condition and 
heavy enough to carry the current your band 
saw will draw. An undersized cord will cause a 
drop in line voltage, resulting in loss of power 
and overheating. Table 1 shows the correct size 
to use depending on cord length and the ampere 
rating on your machine’s nameplate. If in doubt, 
use the next heavier gauge. The smaller the 
gauge number, the heavier the cord. 
Repair or replace a damaged or worn cord 
immediately. 
 
Power
Extension Cord
Currant 
(Amps) 
Line 
voltage 
Cord length 
in feet 
Cord gauge
(AWG) 
0-6 
120 
0 to 25 
18 
25 to 50 
16 
50 to 100 
16 
over 100 
14 
6-10 
120 
0 to 25 
18 
25 to 50 
16 
50 to 100 
14 
over 100 
12 
10-12 
120 
0 to 25 
16 
25 to 50 
16 
50 to 100 
14 
over 100 
12 
12-16 
120 
0 to 25 
14 
25 to 50 
12 
over 50 
not recommended 
 
Table 1