Jet ghd-20 ユーザーズマニュアル

ページ / 24
 
14 
230V operation reconnect the leads as 
shown in (B). 
3.  The 115V attachment plug (C), supplied with 
the drill press, must be replaced with a 
UL/CSA listed plug suitable for 230V 
operation (D).  Contact your local Authorized 
JET Service Center or qualified electrician 
for proper procedures to install the plug.  
The drill press must comply with all local and 
national codes after the 230-volt plug is 
installed. 
4.  The drill press with a 230-volt plug should 
only be connected to an outlet having the 
same configuration as shown in (D). No 
adapter is available nor should be used with 
the 230-volt plug. 
 
Figure 16 
Grounding Instructions 
 
This tool must be grounded while in use to 
protect the operator from electric shock. 
In the event of a malfunction or breakdown, 
grounding provides a path of least resistance for 
electric current to reduce the risk of electric 
shock.  This tool is equipped with an electric 
cord having an equipment-grounding conductor 
and a grounding plug.  The plug must be 
plugged into a matching outlet that is properly 
installed and grounded in accordance with all 
local codes and ordinances. 
Do not modify the plug provided.  If it will not fit 
the outlet, have the proper outlet installed by a 
qualified electrician. 
Improper connection of the equipment-
grounding conductor can result in a risk of 
electric shock.  The conductor, with insulation 
having an outer surface that is green with or 
without yellow stripes, is the equipment-
grounding conductor.  If repair or replacement of 
the electric cord or plug is necessary, do not 
connect the equipment-grounding conductor to a 
live terminal. 
Check with a qualified electrician or service 
personnel if the grounding instructions are not 
completely understood, or if in doubt as to 
whether the tool is properly grounded.  Use only 
three wire extension cords that have three-prong 
grounding plugs and three-pole receptacles that 
accept the tool’s plug. 
Repair or replace a damaged or worn cord 
immediately. 
Extension Cords 
Make sure your extension cord is in good 
condition.  When using an extension cord, be 
sure to use one heavy enough to carry the 
current your machine will draw.  An undersized 
cord will cause a drop in the line voltage 
resulting in power loss and overheating. The 
table following shows the correct size to use 
depending on the cord length and nameplate 
ampere rating.  If in doubt, use the next heavier 
gauge.  Remember, the smaller the gauge 
number, the heavier the cord. 
 
Length of 
Cord 
AWG 
0–25 16 
25-50 14 
51-100 12 
 
The drill press with a 230-volt plug should only 
be connected to an outlet having the same 
configuration (D, Fig. 16). No adapter is 
available or should be used with the 230-volt 
plug. 
Important:  In all cases (115 or 230 volts), make 
certain the receptacle in question is properly 
grounded.  If you are not sure, have a registered 
electrician check the receptacle.