The JJ-8CS and JJ-8HH jointers are rated at 
230V, single phase only.  Confirm that the 
power at the source is compatible with the 
jointer before inserting plug into the outlet. The 
jointer is designed to be used with a plug and 
outlet similar to that shown in Fig. 12. 
Important:  Make certain the receptacle in 
question is properly grounded.  If you are 
not sure, have a registered electrician check 
the receptacle. 
  
Extension Cords 
Make sure the rating of the extension cord is 
suitable for the amperage listed on the 
machine’s motor plate. An undersize cord will 
cause a drop in line voltage resulting in loss of 
power and overheating. 
Use the chart in Figure 13 as a general guide in 
choosing the correct size cord. If in doubt, use 
the next heavier gauge. The smaller the gauge 
number, the heavier the cord. 
 
 
 
Adjustments 
90° Fence Adjustment 
Note: whenever making an adjustment to the 
fence, lift the fence up slightly after releasing the 
lock handle to avoid scratching the table. 
 
1.  Set infeed table to the same height as the 
outfeed table. 
2.  Move the fence by releasing lock handle (A, 
Fig. 14) and pushing the fence assembly 
until it overlaps the tables. 
3.  Adjust the fence to a 90
°
 angle by releasing 
lock handle (B, Fig. 14), pulling up on 
handle (C, Fig. 14), and re-tightening lock 
handle (B, Fig. 14). 
4.  Place a combination square on the infeed 
table. (Fig. 15) 
5.  If fence is not square to table, release lock 
handle (B, Fig. 14), loosen nut (D, Fig. 14), 
and turn bolt (E, Fig. 14) until fence is 
square to table. 
6.  Tighten nut (D, Fig. 14) to retain the setting.  
Tighten lock handle (B, Fig. 14). 
 
 
 
Figure 12 
Recommended Extension Cord Gauges (AWG) 
Extension Cord Length in Feet *  
Amps 
25 50 75 100 150 200 
16 16 16 14 12 12 
5 to 8
16 
16 
14 
12 
10 
NR 
8 to 12
14 
14 
12 
10 
NR 
NR 
12 to 15
12 
12 
10 
10 
NR 
NR 
15 to 20
10 
10 
10 
NR 
NR 
NR 
21 to 30
10 
NR 
NR 
NR 
NR 
NR 
*based on limiting the line voltage drop to 5V at 150% of the 
rated amperes. 
NR: Not Recommended.
 
Figure 13 
 
Figure 14 
 