Jet jwbs-18qt ユーザーガイド

ページ / 52
 
Grounding Instructions 
 This machine must be 
grounded while in use to protect the operator 
from electric shock.
 
In the event of a malfunction or breakdown, 
grounding provides a path of least resistance for 
electric current to reduce the risk of electric 
shock. This machine is equipped with an electric 
cord having an equipment-grounding conductor 
and a grounding plug. The plug must be plugged 
into a matching outlet that is properly installed 
and grounded in accordance with all local codes 
and ordinances. 
Do not modify the plug provided. If it will not fit 
the outlet, have the proper outlet installed by a 
qualified electrician. 
Improper connection of the equipment-
grounding conductor can result in a risk of 
electric shock. The conductor, with insulation 
having an outer surface that is green with or 
without yellow stripes, is the equipment-
grounding conductor. If repair or replacement of 
the electric cord or plug is necessary, do not 
connect the equipment-grounding conductor to a 
live terminal. 
Check with a qualified electrician or service 
personnel if the grounding instructions are not 
completely understood, or if in doubt as to 
whether the tool is properly grounded. Use only 
three wire extension cords that have three-prong 
grounding plugs and three-pole receptacles that 
accept the tool’s plug. 
Repair or replace a damaged or worn cord 
immediately. 
Model JWBS-18QT 
Model JWBS-18QT Band Saw has a 1-3/4 HP 1 
phase motor and is wired from the factory for 
115 volt operation, but can be rewired for 220 
volts. 
115 Volt Operation 
The JWBS-18QT Band Saw comes equipped 
with a plug that looks like A, Fig. 1. and is used 
in an outlet that looks like B, Fig. 1. A temporary 
adapter  
with a grounding ear secured with a 
screw  
(C, Fig. 1) may be used to connect this 
plug to a two-pole receptacle if a properly 
grounded outlet is not available. The temporary 
adapter should only be used until a properly 
grounded outlet can be installed by a qualified 
electrician.  This adapter is not applicable in 
Canada.  
The green colored grounding ear, lug, 
or tab, extending from the adapter, must be 
connected to a permanent ground such as a 
properly grounded outlet box, as shown in 
C, Fig. 1. 
 
Figure 1 
230 Volt Operation 
To convert the JWBS-18QT from 120V to 230V, 
single phase operation, the following is strongly 
recommended: 
Contact your local Authorized JET Service 
Center or qualified electrician for proper 
procedures to install the plug. The band saw 
must comply with all local and national codes 
after the 230V plug is installed. 
The 115V attachment plug supplied with the 
band saw (C, Fig. 2) must be replaced with a 
UL/CSA listed plug suitable for 230V operation 
(D, Fig. 2).  
The band saw with a 230V plug should only be 
connected to an outlet having the same 
configuration (D, Fig. 2). No adapter is available 
or should be used with the 230V plug. 
Important: In all cases (115 or 230 volts), make 
certain the receptacle in question is properly 
grounded. If you are not sure, have a registered 
electrician check the receptacle. 
 
Figure 2