Jet jwl-1442vsk pro woodworking lathe ユーザーガイド

ページ / 32
 
Grounding Instructions 
  This tool must be grounded 
while in use to protect the operator from 
electric shock. 
In the event of a malfunction or breakdown, 
grounding provides a path of least resistance for 
electric current to reduce the risk of electric 
shock. This tool is equipped with an electric cord 
having an equipment-grounding conductor and a 
grounding plug. The plug must be plugged into a 
matching outlet that is properly installed and 
grounded in accordance with all local codes and 
ordinances. 
Do not modify the plug provided. If it will not fit 
the outlet, have the proper outlet installed by a 
qualified electrician. 
Improper connection of the equipment-
grounding conductor can result in a risk of 
electric shock. The conductor, with insulation 
having an outer surface that is green with or 
without yellow stripes, is the equipment-
grounding conductor. If repair or replacement of 
the electric cord or plug is necessary, do not 
connect the equipment-grounding conductor to a 
live terminal. 
Check with a qualified electrician or service 
personnel if the grounding instructions are not 
completely understood, or if in doubt as to 
whether the tool is properly grounded. Use only 
three wire extension cords that have three-prong 
grounding plugs and three-pole receptacles that 
accept the tool’s plug. 
Repair or replace a damaged or worn cord 
immediately. 
115 Volt Operation 
As received from the factory, your sander is 
ready to run at 115-volt operation. This sander, 
when wired for 115 volts, is intended for use on 
a circuit that has an outlet and a plug that looks 
the one illustrated in Figure A. A temporary 
adapter, which looks like the adapter as 
illustrated in Figure B, may be used to connect 
this plug to a two-pole receptacle, as shown in 
Figure B if a properly grounded outlet is not 
available.  
 
The temporary adapter should only be used until 
a properly grounded outlet can be installed by a 
qualified electrician. This adapter is not 
applicable in Canada. 
The green colored rigid 
ear, lug, or tab, extending from the adapter, 
must be connected to a permanent ground such 
as a properly grounded outlet box, as shown in 
Figure B. 
The use of an extension cord is not 
recommended. However, if you must use one 
make sure your extension cord is in good 
condition. Be sure to  use one  heavy enough to 
carry the current your machine will draw. An 
undersized cord will cause a drop in the line 
voltage resulting in power loss and overheating. 
The following table shows the correct size to use 
depending on the cord length needed and the 
nameplate ampere rating. If in doubt, use the 
next heavier gauge. Remember, the smaller the 
gauge number, the heavier the cord. 
Volts 
Total Length of Cord in Feet 
120V 25 
50 
100  150 
AWG 
12-16A 14 
12 
Not 
Recommended 
230 Volt Operation 
If 230V, single-phase operation is desired, the 
following instructions must be followed: 
1.  Disconnect the machine from the power 
source. 
2. This lathe is supplied with four motor leads 
that are connected for 115V operation, as 
shown in Figure A. Reconnect these four 
motor leads for 230V operation, as shown in 
Figure B. 
2. The 115V attachment plug (A), supplied with 
the lathe, must be replaced with a UL/CSA 
listed plug suitable for 230V operation (D). 
Contact your local Authorized Service Center 
or qualified electrician for proper procedures 
to install the plug. The lathe must comply with 
all local and national codes after the 230-volt 
plug is installed. 
3. The lathe with a 230 volt plug should only be 
connected configuration (D). No adapter is 
available or should be used with the 230-volt 
plug. 
Important: In all cases (115 or 230 volts), make 
certain the receptacle in question is properly 
grounded. If you are not sure, have a registered 
electrician check the receptacle.